October 10, 2008Scandinavian Journal of Clinical and Laboratory Investigation81 citations

Analysis of cardiovascular responses to passive head‐up tilt using continuous pulse wave analysis and impedance cardiography

View Full Paper
ATAnna TahvanainenJKJenni KoskelaATAntti Tikkakoski

Key Result

Passive head-up tilt significantly increased diastolic BP, heart rate, and vascular resistance, while decreasing systolic BP, stroke volume, and cardiac output (all p<0.05).

Study Design

Type

Observational (n=33)

Structured PICO

Does passive head-up tilt alter central haemodynamics, arterial stiffness, cardiac function, and vascular resistance compared to the supine position in healthy volunteers?

P
Population
33 healthy volunteers (age 21-51 years)
I
Intervention
Passive head-up tilt with continuous pulse wave analysis, whole-body impedance cardiography, and plethysmographic blood pressure recordings
C
Comparator
Supine position
O
Outcome
Haemodynamic changes (central haemodynamics, arterial stiffness, cardiac function, vascular resistance) and repeatability/reproducibility of the measurement protocolsurrogate

Combined pulse wave analysis and impedance cardiography is a repeatable and reproducible method for comprehensive investigation of cardiovascular function during postural changes.

Main Result

p-value: p=<0.05

Abstract

OBJECTIVE: To non-invasively measure central haemodynamics, arterial stiffness, cardiac function and vascular resistance, with the subject in the supine position and during head-up tilt, in order to examine the haemodynamic changes associated with alterations in the augmentation index, and to investigate repeatability and reproducibility of the measurement protocol. MATERIAL AND METHODS: Thirty-three healthy volunteers (21-51 years) were investigated using continuous pulse wave analysis from the radial artery with a tonometric sensor, whole-body impedance cardiography and plethysmographic blood pressure (BP) recordings from the fingers. The measurements were performed with the subject supine and during passive head-up tilt, and repeated during the same session and on four separate days. RESULTS: During the head-up tilt, diastolic BP (5.2+/-0.6%), heart rate (27.6+/-1.9%) and vascular resistance (12.5+/-1.7%) increased (all p<0.05), while systolic BP (-3.2+/-0.6%), aortic pulse pressure (-23.3+/-1.4%), augmentation index (-11.6+/-0.7%), aortic reflection time (-7.0+/-1.0%), ejection duration (-21.4+/-0.7%), stroke volume (-26.1+/-1.2%) and cardiac output (-5.0+/-1.5%) decreased (all p<0.05). Augmentation index at rest correlated with aortic systolic BP (r = 0.423), aortic reflection time (r = -0.647), pulse wave velocity (r = 0.287) and age (r = 0.480). The change in augmentation index during head-up tilt correlated with the change in aortic systolic BP (r = 0.469), aortic pulse pressure (r = 0.606), ejection duration (r = 0.374) and heart rate (r = -0.445). According to Bland-Altman and repeatability index analyses, repeatability and reproducibility of the measurements were good during the same session and on separate days. CONCLUSIONS: Combined pulse wave analysis and impedance cardiography with the subject in the supine position and during head-up tilt is a repeatable and reproducible method for comprehensive investigation of the cardiovascular function.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tahvanainen et al. (2008) conducted an observational in Healthy volunteers (n=33). Passive head-up tilt vs. Supine position was evaluated on Haemodynamic changes (diastolic BP, heart rate, vascular resistance, systolic BP, stroke volume, cardiac output) (p=<0.05). Passive head-up tilt significantly increased diastolic BP, heart rate, and vascular resistance, while decreasing systolic BP, stroke volume, and cardiac output (all p<0.05).