PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 15, 1997Geophysical Research Letters73 citationsOpen Access

Remote CO, COS, CO2, SO2, HCl detection and temperature estimation of volcanic gas

View Full Paper
TMToshiya MoriKNKenji Notsu

Key Points

Key points are not available for this paper at this time.

Abstract

Volcanic gas from an inaccessible fumarole at Aso volcano, Japan, was recently measured with a Fourier Transform InfraRed (FT‐IR) spectral radiometer. Absorption features of CO, COS, CO 2 , SO 2 , and HCl were identified in the volcanic plume spectra. This is the first time the five volcanic gas components are detected simultaneously by a remote technique. Based on the measured CO/CO 2 ratio of 2.6 × 10 −3 , the equilibrium temperature of the volcanic gas is estimated to be 750° ± 120°C.