PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
September 2, 2011Clinical and Applied Thrombosis/Hemostasis5 citations

“The End of Good Luck’’—Long-Term Survival Without Anticoagulation

View Full Paper
EGEnes Elvin GülGAGökhan AltunbaşMKMehmet Kayrak

Key Result

A 46-year-old man survived 27 years without anticoagulation after mechanical mitral valve replacement, linked to a homozygous VKORC1 mutation maintaining a baseline INR of 1.79.

Study Design

Type

Case Report (n=1)

Multicenter

No

Structured PICO

P
Population
1 patient (46-year-old man) with a metallic prosthetic mitral valve (replaced for severe mitral stenosis) who discontinued warfarin 1 month after surgery.
I
Intervention
No anticoagulation for 27 years
O
Outcome
Long-term survival and valve function without anticoagulation

Long-term survival without anticoagulation in a patient with a mechanical mitral valve may be possible due to genetic mutations in warfarin metabolism (VKORC1) leading to naturally elevated INR.

Abstract

Long-term anticoagulation in patients with metallic prosthetic valve disease is required according to current guidelines. We describe a patient with a functioning mitral mechanical valve without anticoagulation for 27 years. A 46-year-old man admitted to the emergency department with complains of palpitation. The patient had a mitral valve replacement because of severe mitral stenosis. He discontinued warfarin treatment 1 month after surgery because of the unavailability of this drug in Turkey. Transthoracic echocardiography revealed functioning metalic mitral valve with a mean gradient of 9 mm Hg. Fluoroscopy showed normal excursions of the mechanical mitral valve. Transesophageal echocardiography was performed and revealed fresh thrombus formation in the left atrial appendix. Admission international normalized ration (INR) level was 1.79. Due to the higher INR level and long-term survival, genetic analysis of warfarin polymorphism was performed. There was a homozygous mutation in the vitamin K epoxide reductase complex 1 (VKORC1) 1173C>T and 1639G>A genotypes. The possible explanations of long-term survival and baseline higher INR level were linked to the mutation in warfarin metabolism. We also briefly review the literature.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Gül et al. (2011) conducted a case report in Metallic prosthetic valve disease (n=1). Discontinuation of warfarin was evaluated. A 46-year-old man survived 27 years without anticoagulation after mechanical mitral valve replacement, linked to a homozygous VKORC1 mutation maintaining a baseline INR of 1.79.

synapsesocial.com/papers/6a1c9eee1b79c159c356e12dhttps://doi.org/10.1177/1076029611418966
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Long-term survival and complications in patients with mechanical aortic valves without anticoagulation A follow-up study from 1 to 15 years1992 · 15 citations
  2. 2A C1173T Dimorphism in the VKORC1 Gene Determines Coumarin Sensitivity and Bleeding Risk2005 · 123 citations
  3. 3Mechanical aortic valve without anticoagulation for twenty-three years2008 · 11 citations
  4. 4Thirty-seven-year durability of a Starr-Edwards aortic prosthesis: case report and brief review of the literature.2005 · 9 citations
  5. 52008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease2008 · 2,266 citations