January 31, 2024Physiological Reports3 citationsOpen Access

Evaluation of ventricular–vascular coupling with critical care metrics: An in silico approach

View Full Paper
LMLawrence J. MulliganJUJustin UngerleiderAFAdam Friedman

Structured PICO

How does a loss of aortic compliance impact critical care metrics of hemodynamics during steady-state and transient conditions in an in silico model?

P
Population
In silico computational model generating parameters quantifying ventricular-vascular coupling and pressure-volume construct
I
Intervention
Simulation of loss from normal-to-stiff aortic compliance (CA) and decrease in preload during vascular occlusion
C
Comparator
Normal aortic compliance
O
Outcome
Changes in critical care metrics of hemodynamics (pulse pressure, end-systolic pressure, arterial compliance, arterial elastance, dynamic arterial elastance, and mechanical efficiency)surrogate

An in silico model demonstrates that critical care hemodynamic metrics are sensitive to changes in aortic compliance, providing insights into the management of intraoperative hypotension.

Abstract

Abstract Mean arterial pressure and cardiac output provide insufficient guidance for the management of intraoperative hypotension (IOH). In silico models offer additional insights into acute changes in hemodynamic parameters that may be encountered during IOH. A computational model (CM) generated parameters quantifying ventricular–vascular coupling, and pressure–volume construct across levels of aortic compliance (C A ). We studied how a loss from normal‐to‐stiff C A impacts critical care metrics of hemodynamics during vascular occlusion. Pulse pressure (PP), end‐systolic pressure ( P es ), arterial compliance (Art‐ca), arterial elastance (Art‐ea), and dynamic arterial elastance (Eadyn), along mechanical efficiency (ME) were measured at five levels of C A . A loss in C A impacted all variables. During steady‐state conditions, PP, P es , and stroke work increased significantly as C A decreased. Art‐ca decreased and Art‐ea increased similarly; Eadyn increased and ME decreased. During a decrease in preload across all C A levels, arterial dynamics measures remained linear. The CM demonstrated that a loss in C A impacts measures of arterial dynamics during steady‐state and transient conditions and the model demonstrates that critical care metrics are sensitive to changes in C A . While Art‐ca and Art‐ea were sensitive to changes in preload, Eadyn did not change.