CT substitute derived from MRI sequences with ultrashort echo time

View Full Paper
AJAdam JohanssonMKMikael KarlssonTNTufve Nyholm

Key Points

Key points are not available for this paper at this time.

Abstract

PURPOSE: Methods for deriving computed tomography (CT) equivalent information from MRI are needed for attenuation correction in PET/MRI applications, as well as for patient positioning and dose planning in MRI based radiation therapy workflows. This study presents a method for generating a drop in substitute for a CT image from a set of magnetic resonance (MR)images. METHODS: A Gaussian mixture regression model was used to link the voxel values in CT images to the voxel values in images from three MRI sequences: one T2 weighted 3D spin echo based sequence and two dual echo ultrashort echo time MRI sequences with different echo times and flip angles. The method used a training set of matched MR and CT data that after training was able to predict a substitute CT (s-CT) based entirely on the MR information for a new patient. Method validation was achieved using datasets covering the heads of five patients and applying leave-one-out cross-validation (LOOCV). During LOOCV, the model was estimated from the MR and CT data of four patients (training set) and applied to the MR data of the remaining patient (validation set) to generate an s-CT image. This procedure was repeated for all five training and validation data combinations. RESULTS: The mean absolute error for the CT number in the s-CT images was 137 HU. No large differences in method accuracy were noted for the different patients, indicating a robust method. The largest errors in the s-CT images were found at air-tissue and bone-tissue interfaces. The model accurately discriminated between air and bone, as well as between soft tissues and nonsoft tissues. CONCLUSIONS: The s-CT method has the potential to provide an accurate estimation of CT information without risk of geometrical inaccuracies as the model is voxel based. Therefore, s-CT images could be well suited as alternatives to CT images for dose planning in radiotherapy and attenuation correction in PET/MRI.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Johansson et al. (2011) studied this question.

synapsesocial.com/papers/6a1d23411e7099f69104f13bhttps://doi.org/10.1118/1.3578928
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging2003 · 709 citations
  2. 2Advances in Neural Information Processing Systems 71995 · 873 citations
  3. 3MRI-based treatment planning for radiotherapy: Dosimetric verification for prostate IMRT2004 · 159 citations
  4. 4Rapid magnetic resonance quantification on the brain: Optimization for clinical usage2008 · 505 citations
  5. 5On Gaussian radial basis function approximations: interpretation, extensions, and learning strategies2002 · 40 citations