PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
August 11, 2017American Journal of Noninvasive Cardiology7 citations

Noninvasive Quantitative Assessment of Segmental MyocardialWall Motion Using Technetium-99m 2-Methoxy-Isobutyl-IsonitrileScintigraphy

View Full Paper
PMPaolo MarzulloCMClaudio MarcassaOPOberdan Parodi

Key Points

  • This study aims to introduce a quantitative index for assessing segmental myocardial wall motion using MIBI scintigraphy.
  • Analyzed 20 coronary artery disease patients and 10 normal subjects using MIBI scintigraphy and contrast ventriculography.

Structured PICO

Does a count-based wall thickening index derived from Technetium-99m MIBI scintigraphy accurately assess regional myocardial wall motion compared to contrast ventriculography in patients with CAD and normal subjects?

P
Population
30 subjects (20 patients with coronary artery disease and regional wall motion abnormalities, and 10 normal subjects)
I
Intervention
Technetium-99m methoxy-isobutyl-isonitrile (MIBI) scintigraphy with calculation of a count-based wall thickening index from perfusion electrocardiogram-gated images
C
Comparator
Contrast ventriculography
O
Outcome
Overall agreement between radioisotopic and ventriculographic techniques in assessing regional wall motionsurrogate

A count-based wall thickening index from Technetium-99m MIBI scintigraphy accurately assesses regional myocardial wall motion, showing 88% agreement with contrast ventriculography.

Abstract

Technetium-99m methoxy-isobutyl-isonitrile (MIBI) has been recently introduced to trace regional myocardial perfusion; the first-pass and the equilibrium-gated images have been also used to assess myocardial function. In the present study, a quantitative index of regional myocardial wall motion obtained from perfusion electrocardiogram-gated images is proposed. The assumption of the study is based on the partial volume effect, i.e. changes in radioactivity counts correlated with variations in the object size. On this basis, changes in the detected radioactivity reflect changes in myocardial wall thickness during the cardiac cycle. Twenty patients with coronary artery disease and regional wall motion abnormalities and 10 normal subjects were studied by MIBI scintigraphy and contrast ventriculography; regional wall motion was analyzed by a radial method applied to both techniques. In each patient, absolute systolic changes in radioactivity and its ratio to normal reference values were determined in 9 anatomical cardiac regions according to the formula: (end-systolic counting profile - end-diastolic counting profile/ end-diastolic counting profile) X 100. These values were compared with the quantitative wall motion of corresponding segments obtained from contrast ventriculography. The overall agreement between radioisotopic and ventriculographic techniques was 88% (158 of 180 segments). The intra- and interobserver variations in the measurements of the scintigraphic wall thickening index were ± 5.4 and ± 4.1 %, respectively. Normal, hypokinetic and akinetic ventriculographic segments showed wall thickening index values of 1.1 ± 0.19, 0.82 ± 0.2 and 0.45 ± 0.3, respectively (p < 0.001). Thus, the count-based wall thickening index, reflecting systo-diastolic transmurai radioactivity changes, provides an alternative means for the complementary evaluation of regional myocardial wall motion during perfusion studies with MIBI.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Marzullo et al. (2017) studied this question.

synapsesocial.com/papers/6a1d3a70750575be8d2f4e14https://doi.org/10.1159/000470505
Ask AI
Helpful
Bookmark
Share
View Full Paper