PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 1, 1983Acta Anaesthesiologica Scandinavica7 citations

Stroke Volume Measured by Pulsed Ultrasound Doppler and M‐Mode Echocardiography

View Full Paper
TLT Lang‐JensenJBJens BerningEJE. Jacobsen

Structured PICO

Does stroke volume measured by pulsed ultrasound Doppler and M-mode echocardiography correlate with thermodilution in patients with a Swan-Ganz catheter?

P
Population
6 patients with a Swan-Ganz catheter
I
Intervention
Stroke volume measurement using pulsed ultrasound Doppler (for aortic bloodstream velocity) and M-mode echocardiography (for aortic diameter)
C
Comparator
Stroke volume measurement by thermodilution technique performed simultaneously
O
Outcome
Correlation of calculated stroke volumes between the Doppler-Echo method and the thermodilution techniquesurrogate

Pulsed ultrasound Doppler combined with M-mode echocardiography provides a non-invasive method to measure stroke volume and cardiac output.

Abstract

The velocity of the bloodstream in the ascending aorta was measured by pulsed ultrasound Doppler. The diameter of the aorta was measured by M-mode echocardiography. Forty-three measurements were performed in six patients, who all had a Swan-Ganz catheter. The calculated stroke volumes from the Doppler-Echo method were compared with the stroke volumes measured by the thermodilution technique, which was performed simultaneously with the Doppler measurements. The correlation between the measurements was good (r = 0.08). It is concluded that it is possible non-invasively to measure stroke volume (and cardiac output) by means of ultrasound Doppler and an echocardiograph.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lang‐Jensen et al. (1983) studied this question.

synapsesocial.com/papers/6a1df1885c054b78c2ef97d4https://doi.org/10.1111/j.1399-6576.1983.tb01986.x
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Transcutaneous measurement of blood flow velocity in the human aorta1976 · 90 citations
  2. 2Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.1978 · 7,485 citations
  3. 3Velocity distribution in aortic flow1973 · 57 citations
  4. 4Comparison of methods to calculate cardiac output using the CO2 rebreathing method1976 · 41 citations
  5. 5Transcutaneous directional flow detection: A preliminary report1969 · 49 citations