June 3, 2026Journal of Hypertension0 citations

A Unified Software Platform for Integrated Structural and Functional Carotid Ultrasound Assessment

View Full Paper
EBElisabetta BianchiniSOStefan OrtenSWSiegfried Wassertheurer

Key Result

A unified ultrasound-based software platform accurately estimated central aortic pressure waveforms compared to tonometry (RMSE 3.17 ± 1.58 mmHg; r=0.96 ± 0.04) with good repeatability.

Key Points

  • This work aims to develop a unified software platform for comprehensive vascular health assessment integrating structural and functional analyses.
  • Developed a unified ultrasound-based software platform from ARCSolver and Carotid Studio devices.
  • Extracted structural metrics from ultrasound and derived aortic pressure waveforms using a new transfer function.
  • Evaluated system performance and usability in a pilot study with 14 healthy volunteers.
  • Functional parameters showed good repeatability with ICC for heart rate = 0.907, central systolic blood pressure = 0.984, and augmentation index = 0.741.
  • Waveform comparison to reference measurements yielded RMSE of 3.17 ± 1.58 mmHg and correlation coefficient of 0.96 ± 0.04.
  • Usability testing revealed high acceptance by clinical operators.

Study Design

Type

Cross-Sectional (n=14)

Structured PICO

Does a unified ultrasound-based software platform accurately and reliably estimate central hemodynamic indices compared to reference tonometry in healthy volunteers?

P
Population
14 healthy volunteers evaluated in a pilot study to assess a unified ultrasound-based software platform against reference tonometric measurements.
E
Exposure
Unified ultrasound-based software platform (integrating ARCSolver and Carotid Studio with a newly developed generalized transfer function [newGTF])
C
Comparator
Reference tonometric measurements
O
Outcome
Waveform reconstruction accuracy (RMSE and correlation coefficient) and repeatability (ICC)surrogate

A novel integrated ultrasound-based software platform demonstrates high accuracy and repeatability for combined structural and functional carotid artery assessment compared to reference tonometry.

Main Result

Effect estimate: RMSE 3.17 ± 1.58 mmHg; r=0.96 ± 0.04

Abstract

Objective: A comprehensive evaluation of vascular health relies on the analysis of both structural and functional biomarkers. In current practice, these parameters are typically derived from separate technologies, such as imaging and applanation tonometry, resulting in fragmented approaches. This work addresses the need for an integrated solution by presenting the development and preliminary assessment of a unified ultrasound-based software platform for carotid artery analysis. Design and method: The proposed platform was built upon two previously validated medical devices (the ARCSolver and the Carotid Studio) enhanced through new modules and an integration strategy, enabling full interoperability between structural and functional analyses. Structural metrics, including carotid diameter and intima-media thickness, were extracted from longitudinal ultrasound acquisitions using the Carotid Studio. In parallel, a newly developed generalized transfer function (newGTF) was developed to derive aortic pressure waveforms from ultrasound-based diameter signals, allowing ARCSolver algorithms to estimate central hemodynamic indices via pulse wave analysis. System performance, with a focus on the newGTF, were evaluated in a pilot study involving repeated measurements in 14 healthy volunteers, using paired carotid ultrasound recordings and reference tonometric measurements. Comparison with the reference method was assessed for waveform reconstruction, while precision was examined through repeatability assessment. Usability was additionally evaluated by a group of clinical operators. Results: The integrated software provides a user-friendly graphical interface enabling, from a single ultrasound acquisition, local geometric analysis and model- and machine-learning–based waveform transformation to estimate central aortic pressure. Intraclass Correlation Coefficient, ICC, of the functional parameters demonstrated good repeatability (ICC for heart rate = 0.907, 95% CI: 0.736–0.969; ICC for central systolic blood pressure = 0.984, 95% CI: 0.952–0.995, ICC for augmentation index = 0.741, 95% CI: 0.384–0.908) and waveform comparison with tonometric reference measurements showed root mean square error RMSE of 3.17 ± 1.58 mmHg and correlation coefficient of 0.96 ± 0.04. Usability testing indicated a high level of acceptance among operators. Conclusions: This integrated ultrasound-based platform enables combined structural and functional vascular assessment within a single software environment and represents a promising tool for both research and clinical applications.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bianchini et al. (2026) conducted a cross-sectional in Healthy (n=14). Unified ultrasound-based software platform vs. Reference tonometric measurements was evaluated on Waveform comparison with tonometric reference measurements (RMSE 3.17 ± 1.58 mmHg; r=0.96 ± 0.04). A unified ultrasound-based software platform accurately estimated central aortic pressure waveforms compared to tonometry (RMSE 3.17 ± 1.58 mmHg; r=0.96 ± 0.04) with good repeatability.

synapsesocial.com/papers/6a1fc42cdee9eb8c0dce5c2bhttps://doi.org/10.1097/01.hjh.0001195160.25252.e9