PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 5, 2007Acta Anaesthesiologica Scandinavica15 citationsOpen Access

Beat‐to‐beat change in ‘myocardial performance index’ related to load

View Full Paper
MHMichael HaneyUmeå UniversityRARoman A’rochUniversity Hospital of UmeåGJG. JohanssonUmeå University

Key Result

Myocardial performance index (MPI) is strongly load-dependent, demonstrating a strong linear relationship to pre-load and after-load and increasing progressively during decreasing end-diastolic volume.

Structured PICO

Does the myocardial performance index (MPI) change with beat-by-beat alterations in pre-load under static contractile status in a porcine model?

P
Population
Eight anesthetized juvenile pigs undergoing transient inflation of a vena cava balloon catheter to produce controlled pre-load alterations.
I
Intervention
Transient inflation of a vena cava balloon catheter to produce controlled pre-load alterations, and two pharmacologic inotropic interventions
O
Outcome
Relationship of myocardial performance index (MPI) to beat-by-beat change in pre-load and after-loadsurrogate

The myocardial performance index is strongly load-dependent, suggesting its clinical utility in critically ill patients with varying loading conditions may be limited.

Abstract

BACKGROUND: This study was designed to assess the relationship of the "myocardial performance index" (MPI) to the beat-by-beat change in pre-load with static or unchanged contractile status. METHODS: Eight anesthetized juvenile pigs were studied using direct measurement of the left ventricular pressure and volume. Transient inflation of a vena cava balloon catheter produced controlled pre-load alterations. Consecutive beats were analyzed, grouped for first, second, third, etc. during the pre-load alteration, and evaluated for the change in MPI during the same contractile status with a controlled pre-load alteration. Two pharmacologic inotropic interventions were also included to generate several myocardial conditions in each animal. RESULTS: MPI demonstrated a strong linear relationship to the pre-load and after-load. MPI increased progressively during decreasing end-diastolic volume, mostly related to changes in ejection time. MPI was observed at the same level for three different myocardial function conditions (all eight animals), with a different relationship between MPI and pre-load noted for each observation. CONCLUSIONS: MPI is strongly load dependent, and can vary widely in value for the same contractile status if the load is varied. The use of this index in critically ill patients should be limited in this respect. Further work is needed to establish the relationship of MPI to load and contractile status.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Haney et al. (2007) studied this question. Transient inflation of a vena cava balloon catheter (pre-load alteration) was evaluated on Change in myocardial performance index (MPI) during pre-load alteration. Myocardial performance index (MPI) is strongly load-dependent, demonstrating a strong linear relationship to pre-load and after-load and increasing progressively during decreasing end-diastolic volume.

synapsesocial.com/papers/6a1ff09a3224f8dacd0da985https://doi.org/10.1111/j.1399-6576.2007.01287.x
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1The effects of changes in loading conditions and modulation of inotropic state on the myocardial performance index: comparison with conductance catheter measurements2004 · 142 citations
  2. 2Influence of Cardiac Function and Loading Conditions on the Myocardial Performance Index – Theoretical Analysis Based on a Mathematical Model –2015 · 13 citations
  3. 3Estimation of myocardial performance in CABG patients2004 · 17 citations
  4. 4Effects of changes in loading conditions and heart rate on the myocardial performance index in cats2007 · 8 citations
  5. 5Myocardial performance index during rapidly changing loading conditions2007 · 9 citations