March 1, 1982Clinical Chemistry363 citationsOpen Access

Rapid assay for amino acids in serum or urine by pre-column derivatization and reversed-phase liquid chromatography.

View Full Paper
DTD C TurnellJCJonathan D. Cooper

Key Points

Key points are not available for this paper at this time.

Abstract

This method for estimating clinically important amino acids in serum or urine within 40 min involves o-phthalaldehyde/2-mercaptoethanol derivatization and reversed-phase "high-pressure" liquid chromatography. Homocysteic acid is an internal standard, and homoserine and norvaline are reference peaks. For all the amino acids estimated, the between-run coefficients of variation ranged from 2.0 to 13.5%, and the mean analytical recoveries from both serum and urine samples was 101%. Peak areas vary linearly with concentration up to 1500 mumol/L for all the amino acids assayed. The limit of detection for each amino acid was estimated to be 38 fmol.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Turnell et al. (1982) studied this question.

synapsesocial.com/papers/6a208700e1fa5be4a5f4238dhttps://doi.org/10.1093/clinchem/28.3.527