July 1, 1992Hypertension206 citations

Conduit artery compliance and distensibility are not necessarily reduced in hypertension.

View Full Paper
DHDaniel HayozVascular MedicineBRBlaise RutschmannHôpital de MorgesFPFlorent PerretUniversité Claude Bernard Lyon 1

Key Points

  • The study aims to determine if hypertension alters the elastic behavior of conduit arteries in humans and rats.
  • Noninvasive measurement of arterial compliance-pressure curves using echo-tracking and photoplethysmography.

Structured PICO

Does hypertension alter the elastic behavior of conduit arteries in humans and rats?

P
Population
17 newly diagnosed hypertensive patients and 17 age- and sex-matched normotensive controls, along with 14 16-week-old anesthetized spontaneously hypertensive rats and 15 Wistar-Kyoto normotensive rats.
I
Intervention
Hypertension (observational)
C
Comparator
Normotension
O
Outcome
Arterial cross-sectional compliance-pressure and distensibility-pressure curvessurrogate

Conduit artery compliance and distensibility are not necessarily reduced in hypertension in both humans and rats.

Abstract

The goal of this study was to investigate whether the elastic behavior of conduit arteries of humans or rats is altered as a result of concomitant hypertension. Forearm arterial cross-sectional compliance-pressure curves were determined noninvasively by means of a high precision ultrasonic echo-tracking device coupled to a photoplethysmograph (Finapres system) allowing simultaneous arterial diameter and finger blood pressure monitoring. Seventeen newly diagnosed hypertensive patients with a humeral blood pressure of 163/103 +/- 4.4/2.2 mm Hg (mean +/- SEM) and 17 age- and sex-matched normotensive controls with a humeral blood pressure of 121/77 +/- 3.2/1.9 mm Hg were included in the study. Compliance-pressure curves were also established at the carotid artery of 16-week-old anesthetized spontaneously hypertensive rats (n = 14) as well as Wistar-Kyoto normotensive animals (n = 15) using the same echo-tracking device. In these animals, intra-arterial pressure was monitored in the contralateral carotid artery. Mean blood pressures averaged 197 +/- 4 and 140 +/- 3 mm Hg in the hypertensive and normotensive rats, respectively. Despite the considerable differences in blood pressure, the diameter-pressure and cross-sectional compliance-pressure and distensibility-pressure curves were not different when hypertensive patients or animals were compared with their respective controls. These results suggest that the elastic behavior of a medium size muscular artery (radial) in humans and of an elastic artery (carotid) in rats is not necessarily altered by an increase in blood pressure.