January 22, 2014Journal of Composites for Construction110 citationsOpen Access

Plastic Hinge Length of FRP-Confined Square RC Columns

View Full Paper
CJCheng JiangYWYu‐Fei WuGWGang Wu

Key Points

Key points are not available for this paper at this time.

Abstract

The confinement effect of fiber-reinforced polymer (FRP) jacket on the plastic hinge length of square RC columns is studied through experimental testing and analytical study. Seven half-scale RC square columns with different confinement ratios were tested. The strain of longitudinal reinforcement bars and the extent of yielding were measured by strain gauges mounted inside the reinforcement bars. The variation of the strain field of the external column face was recorded continuously by digital image correlation (DIC) during a test. More rational approaches of data analysis are used for identification of plastic hinge length from measured strain fields. The obtained results show that compared with unconfined RC columns, FRP jacketing increases the plastic hinge length when the confinement level is low, but reduces it when the confinement level is high. The analytical study shows that all existing models of plastic hinge length are inadequate in one way or another because no model includes all important factors. The proposed model can correctly capture the trends but it needs to be further improved for accuracy when more data are available.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jiang et al. (2014) studied this question.

synapsesocial.com/papers/6a2103f3a95306f617123ca2https://doi.org/10.1061/(asce)cc.1943-5614.0000463
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Inelastic design of reinforced concrete beams and limited ductile high-strength concrete columns2003 · 17 citations
  2. 2Confined Concrete Columns With Stubs1993 · 228 citations
  3. 3Digital image correlation analysis of interfacial debonding properties and fracture behavior in concrete2006 · 226 citations
  4. 4Seismic Design Guidelines for Squat Composite- Jacketed Circular and Rectangular Reinforced Concrete Bridge Columns2005 · 20 citations
  5. 5Effect of corner radius on the performance of CFRP-confined square concrete columns: Test2007 · 498 citations