Buffer Gas Pressure Optimization for Atomic Spin Relaxation Suppression in Ultra-High-Sensitivity SERF Magnetometers

View Full Paper
SLSiran LiXLX.-G. LuYZYinghui Zhang

Key Points

  • This research aims to optimize buffer gas pressure to suppress atomic spin relaxation in SERF magnetometers to enhance sensitivity.
  • Constructed an analytical model of total relaxation rate including various relaxation mechanisms.
  • Derived the relationship between buffer gas pressure and total relaxation rate for a spherical vapor cell.
  • Carried out experimental measurements to validate theoretical results.
  • The theoretical model matched experimental results closely, indicating successful optimization of buffer gas pressure.
  • Optimization led to enhanced sensitivity of SERF magnetometers for remote sensing applications.

Abstract

Optically pumped magnetometers (OPM) are core quantum payloads for geomagnetic remote sensing. Among them, the spin-exchange relaxation-free (SERF) OPM with aT-level ultimate sensitivity stands as mainstream. While enlarging the alkali-metal vapor cell of the SERF OPM enhances sensitivity, it triggers complex atomic spin relaxation, notably intensified magnetic field gradient relaxation. To address the dilemma of atomic spin relaxation regulation and the engineering requirements of ultra-high-sensitivity SERF magnetometers, this paper constructs an analytical model of the total relaxation rate that comprehensively considers wall-collision relaxation, spin-destruction collision relaxation, and longitudinal/transverse magnetic field gradient relaxation, etc. The analytical relationship between buffer gas pressure and total relaxation rate for a commonly used spherical vapor cell is derived, revealing the intrinsic correlation among cell size, atomic spin relaxation, and optimal pressure. Based on the theoretical model, the filling parameters of the vapor cell are optimized, and experimental measurements are carried out. The theoretical relaxation results are highly consistent with the experimental ones, realizing the precise optimization of buffer gas pressure. The optimization method proposed in this paper provides a theoretical basis and parameter guidance for the engineering preparation of alkali-metal vapor cells for high-sensitivity SERF magnetometers in remote sensing applications.