PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 4, 2026Scandinavian Journal of Clinical and Laboratory Investigation0 citationsOpen Access

Preanalytical effects on the ELF score and its component biomarkers; aminoterminal peptide of type III procollagen (PIIINP), hyaluronic acid (HA) and tissue inhibitor of metalloproteinases-1 (TIMP-1)

View Full Paper
MBManar BitarDSDieter SamynMHMadeleine Helgesson

Key Points

  • To evaluate how preanalytical factors influence the measurement of PIIINP, HA, TIMP-1, and ELF score.
  • Analyzed serum pools with added hemolysate concentrates.
  • Centrifuged blood samples from 30 donors at various time points (0-24 hours) post-collection.
  • Assessed changes in biomarker concentrations relative to baseline.
  • PIIINP showed a 10% reduction in concentration at 0.5 g/L free hemoglobin.
  • HA and TIMP-1 remained stable even at 10 g/L hemolysis, with minimal impact on the ELF score.
  • TIMP-1 concentrations fluctuated after 4 hours of centrifugation delays, although thus having negligible impact on ELF score.

Abstract

BACKGROUND: The Enhanced Liver Fibrosis (ELF) score, which combines aminoterminal peptide of type III procollagen (PIIINP), hyaluronic acid (HA) and tissue inhibitor of metalloproteinases-1 (TIMP-1), is a clinically relevant tool for assessing liver fibrosis. This study examines the effect of preanalytical factors on the measurement of PIIINP, HA, TIMP-1 and the ELF score. METHODS: Serum pools spanning the measurement range of ELF biomarkers were spiked with increasing concentrations of hemolysate. Additionally, blood samples from 30 donors were centrifuged at 0-, 4-, 8-, and 24-hours post-collection. The influence of these factors was assessed by calculating the percentage difference in measured concentrations compared to baseline, and the underlying mechanisms were investigated. RESULTS: PIIINP showed significant susceptibility to hemolysis, with a 10% reduction in analyte concentration already at 0.5 g/L free hemoglobin. HA and TIMP-1 remained stable even at 10 g/L, and the ELF score up to 4 g/L. The effect on PIIINP cannot be explained by proteolytic activity, or assay components, but may be linked to direct effects of hemoglobin on the PIIINP molecule. Pre-centrifugation delays up to 8 h had minimal impact on PIIINP and HA measurements, whereas TIMP-1 concentrations fluctuated dramatically already after 4 h, but this had a negligible impact on the ELF score. CONCLUSION: Hemolysis significantly interferes with PIIINP measurement, and centrifugation delays particularly affect TIMP-1 measurement in serum, whereas the ELF-score remains robust. These findings highlight the need for thorough investigation of preanalytical factors of an assay alongside the manufacturer's instruction.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bitar et al. (2026) studied this question.

synapsesocial.com/papers/6a2116cfd499ed480b16fc97https://doi.org/10.1080/00365513.2026.2679460
Ask AI
Helpful
Bookmark
Share
View Full Paper