June 4, 2026BMC Oral Health0 citationsOpen Access

Marginal fit of crowns fabricated via simultaneous digital workflows for integrated fiber post-and-core and crown: an in vitro study

XGXiaoyang GuoYXYundeng XiaowenMGMaomao Gao

Key Points

  • This study aims to assess the marginal fit of crowns produced by digital workflows versus a conventional approach.
  • Thirty mandibular first premolars randomly assigned to three groups (n=10): traditional step-by-step, digital cast splicing, and physical polyether cast.
  • Crowns fabricated using computer-aided design and manufacturing (CAD-CAM) and evaluated with microcomputed tomography.
  • Marginal and internal fit evaluated at 16 locations and statistical analyses performed with α = 0.05.
  • No significant differences for average intracoronary cement thickness (P = 0.083) and axial occlusal intersection gap (P = 0.204).
  • Significant differences for marginal gap (P = 0.022), axial wall gap (P = 0.004), and occlusal gap (P < 0.001).
  • All measurements remained within a clinically acceptable threshold of 120 μm.

Abstract

Abstract Background For teeth with extensive structural defects, the post-and-core crown is a well-established, but multi-visit approach to preserving the natural tooth. Digital workflows enable simultaneous fabrication of the post-and-core and crown; however, the marginal fit of the crown produced by these workflows—a critical indicator of clinical performance—has not been systematically assessed. This in vitro study aimed to compare crown fit between two simultaneous digital workflows and a conventional sequential method. Methods Thirty intact mandibular first premolars were randomly assigned to three groups ( n = 10): traditional step-by-step workflow (TSS group), digital cast splicing method (DSM group), and physical polyether cast (PPC group). All restorations were fabricated using computer-aided design and manufacturing (CAD-CAM) and subsequently cemented. Marginal and internal fit were assessed using microcomputed tomography (micro-CT). The adhesive volume and surface area of the abutment teeth were quantified three-dimensionally to calculate the average intracoronary cement thickness (AICT). The crown fit was evaluated in two dimensions at 16 locations, including the marginal gap (MG), axial wall gap (AWG), axial occlusal intersection gap (AOG), and occlusal gap (OG). Statistical analyses were conducted using appropriate parametric or non-parametric tests with a significance level of α = 0.05. Results No significant differences were observed among the three workflows for AICT ( P = .083) and AOG ( P = .204). Significant inter-group differences were found for MG ( P = .022), AWG ( P = .004), and OG ( P < .001) regarding the 2D parameters. Specifically, the DSM group exhibited a larger MG than the TSS and PPC groups; the PPC group demonstrated a larger AWG than the TSS and DSM groups; and the TSS group showed a larger OG than both the PPC and DSM groups. Despite these statistical differences, all measured values remained within the 120 μm threshold. Conclusion Simultaneous digital fabrication of integrated post-and-core crowns achieved a clinically acceptable marginal fit. Within the limitations of this in vitro study, digital workflows represent a reliable alternative to conventional multi-visit protocols for the fabrication of integrated post-and-core and crowns. Trial registration This study involves ex vivo experiments using extracted teeth (biological samples) and does not qualify as a clinical trial. Therefore, clinical trial registration does not apply to this study.