PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 1, 1987Journal of Cerebral Blood Flow & Metabolism176 citationsOpen Access

A System for Cerebral Blood Flow Measurement Using an H 2 15 O Autoradiographic Method and Positron Emission Tomography

IKIwao KannoHIHidehiro IidaSMShuichi Miura

Key Points

Key points are not available for this paper at this time.

Abstract

A system for CBF measurement using an H215O autoradiographic method and positron emission tomography (PET) has been designed and installed as a clinical tool. Following an intravenous injection of H215O, a radioactivity accumulation in the brain tissue for 60 s and a continuous record of radioactivity in arterial blood were measured by a high counting speed PET device and a beta-ray detector, respectively, and CBF was calculated by a table-lookup procedure. First, this method was compared with the C15O2 inhalation steady-state method on 17 cerebrovascular disease patients and four normal subjects. The two values for CBF agreed with each other when H215O autoradiographic method was applied by correction for the dispersion in the measured arterial radioactivity-time curve. However, without the correction, the CBF by the H215O autoradiographic method revealed substantial overestimation by 30.6 +/- 17.5%. A reduced gray/white ratio of CBF was also observed in the H215O autoradiographic method. Second, simulation was performed in order to determine optimal accumulation time by PET scan; the result was that errors due to dispersion and time mismatch became critical as the accumulation time was shortened to less than 60 s.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kanno et al. (1987) studied this question.

synapsesocial.com/papers/6a211dc4a37b8f8d92968e9fhttps://doi.org/10.1038/jcbfm.1987.37
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Error Analysis of a Quantitative Cerebral Blood Flow Measurement Using H 2 15 O Autoradiography and Positron Emission Tomography, with Respect to the Dispersion of the Input Function1986 · 377 citations
  2. 2What is the Correct Value for the Brain-Blood Partition Coefficient for Water?1985 · 715 citations
  3. 3Error Analysis for the Determination of Cerebral Blood Flow with the Continuous Inhalation of 15O-Labeled Carbon Dioxide and Positron Emission Tomography1982 · 63 citations
  4. 4A Theoretical Study of the Steady-State Model for Measuring Regional Cerebral Blood Flow and Oxygen Utilisation Using Oxygen-151981 · 141 citations
  5. 5Deadtime correction method using random coincidence for PET.1986 · 27 citations