May 18, 2022Advanced Functional Materials67 citationsOpen Access

Realizing Simultaneous X‐Ray Imaging and Dosimetry Using Phosphor‐Based Detectors with High Memory Stability and Convenient Readout Process

View Full Paper
ZYZetian YangJHJieqi HuDHDavid Van der Heggen

Key Points

Key points are not available for this paper at this time.

Abstract

Abstract Flexible X‐ray storage phosphor sheets are regarded as promising alternatives to conventional electronic flat‐panel X‐ray detectors, enabling X‐ray imaging and dosimetry in less accessible situations. However, it is a challenge to develop phosphor‐based detectors with high memory stability and convenient readout processes. Here, an approach to realize this using radiation‐induced photoluminescence tuning in (Ba 1‐ x Sr x ) 2 SiO 4 :Eu phosphors is demonstrated, ascribed to the reduction of Eu 3+ toward Eu 2+ . The associated photoluminescence spectral change and the accompanying color contrast in response to the radiation dose are exploited for simultaneous X‐ray dosimetry and imaging. The recorded image can be read out conveniently by a regular photo camera upon UV illumination and the radiation dose can be extracted during the imaging process in a ratiometric way via the green to red pixel intensity, avoiding the need for absolute intensity measurement. Moreover, the imaged information can be maintained for longer than 28 days and the plate can be reused for X‐ray detection after bleaching upon 420 nm illumination, exhibiting superior memory retention ability and good cycling resistance. These results reveal the great potential of (Ba 1‐ x Sr x ) 2 SiO 4 :Eu for X‐ray‐based microbeam radiation therapy and nondestructive inspection and are expected to stimulate research on phosphor‐based photoluminescence modulated detectors.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Yang et al. (2022) studied this question.

synapsesocial.com/papers/6a21ebfd3b8e99975a4e93efhttps://doi.org/10.1002/adfm.202201684
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Imaging radiation dose in breast radiotherapy by X-ray CT calibration of Cherenkov light2020 · 73 citations
  2. 2Total reflection X-ray fluorescence as a tool for food screening2015 · 77 citations
  3. 3X-ray based methods for non-destructive testing and material characterization2008 · 254 citations
  4. 4Theory of thermoluminescence2006 · 570 citations
  5. 5Characterization of optically stimulated luminescent dosimeters, OSLDs, for clinical dosimetric measurements2007 · 392 citations