PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 14, 2003Journal of Analytical Atomic Spectrometry215 citations

The nature and sources of laser induced isotopic fractionation in laser ablation-multicollector-inductively coupled plasma-mass spectrometry

View Full Paper
SJSimon E. JacksonDGDetlef Günther

Key Points

Key points are not available for this paper at this time.

Abstract

Coupling laser ablation sampling with MC-ICP-MS detection allows rapid, in situ determination of isotope ratios. However, measured isotope ratios can show large biases relative to the true ratio. We show that, at low laser pulse energies (3 J cm−2), the laser ablation aerosol of copper metal possessed a 65Cu/63Cu ratio that deviated by more than 12 ε units (12 parts per 10,000) from that of the sample. At high pulse energies (9 J cm−2 and above), near isotopically stoichiometric ablation generally occurred. However, even at high pulse energies, on-line laser ablation-MC-ICP-MS Cu isotope ratios showed large biases (15–48 ε units) from the target sample. Filtering larger particles (>0.5 µm) from the ablation aerosol was accompanied by a reduction in signal that was generally much smaller than the associated reduction in volume transport (a factor of 2.8–84 for ablations in Ar), suggesting that volatilisation and ionisation of particles in the ICP was incomplete. Filtered aerosols always yielded isotopic values that were closer to the true value than unfiltered aerosols by an average of 18 ε units. These data suggest that, while significant isotopic fractionation occurred at the ablation site at low laser fluence, the dominant source of isotopic fractionation at high laser fluence was the preferential volatilisation of 63Cu during incomplete vaporisation and ionisation in the ICP of particles greater than approximately 0.5 µm in diameter.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jackson et al. (2003) studied this question.

synapsesocial.com/papers/6a2204df4ae3d5108796eaa0https://doi.org/10.1039/b209620j
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Magma recharge, contamination and residence times revealed by in situ laser ablation isotopic analysis of feldspar in volcanic rocks2001 · 231 citations
  2. 2In situ hafnium isotope ratio analysis of zircon by inductively coupled plasma multiple collector mass spectrometry1995 · 128 citations
  3. 3Precise analysis of copper and zinc isotopic compositions by plasma-source mass spectrometry1999 · 1,322 citations
  4. 4Isotopic analysis of zirconium using enhanced sensitivity-laser ablation-multiple collector-inductively coupled plasma mass spectrometry1999 · 29 citations
  5. 5Mass fractionation processes of transition metal isotopes2002 · 471 citations