PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 2, 2009Nuclear Medicine Communications106 citations

Comparison of V/Q SPECT and planar V/Q lung scintigraphy in diagnosing acute pulmonary embolism

View Full Paper
HGHenrik GutteJMJann MortensenCJClaus V. Jensen

Structured PICO

Does V/Q SPECT improve diagnostic accuracy for acute pulmonary embolism compared to planar V/Q scintigraphy in patients with suspected PE?

P
Population
36 consecutive patients suspected of acute pulmonary embolism with positive D-dimer (>0.5 mg/l) or Wells score >2
I
Intervention
Three-dimensional V/Q SPECT
C
Comparator
Planar V/Q scintigraphy
O
Outcome
Diagnostic performance (sensitivity and specificity) for acute pulmonary embolismsurrogate

V/Q SPECT offers superior sensitivity and specificity compared to planar V/Q scintigraphy for the diagnosis of acute pulmonary embolism.

Abstract

PURPOSE: Planar ventilation/perfusion (V/Q) scintigraphy is currently the standard method for the diagnosis of pulmonary embolism (PE) in most nuclear medicine centers. However, recent studies have shown a superior sensitivity and specificity when applying V/Q single photon emission computed tomography (SPECT) in diagnosing PE. This study evaluated the diagnostic performance of three-dimensional V/Q SPECT in comparison with planar V/Q scintigraphy. MATERIALS AND METHODS: Consecutive patients suspected of acute PE from June 2006 to February 2008 were referred to the Department of Nuclear Medicine at Frederiksberg Hospital, Denmark to a V/Q SPECT, as the first-line imaging procedure. Patients with positive D-dimer (>0.5 mg/l) or after clinical assessment with a Wells score of more than 2 were included and had a V/Q SPECT, low-dose CT, planar V/Q scintigraphy, and pulmonary multidetector computer tomography angiography performed the same day. Ventilation studies were performed using Kr. Patient follow-up was at least 6 months. RESULTS: A total of 36 patient studies were available for analysis, of which 11 (31%) had PE. V/Q SPECT had a sensitivity of 100% and a specificity of 87%. Planar V/Q scintigraphy had a sensitivity of 64% and a specificity of 72%. CONCLUSION: We conclude that V/Q SPECT has a superior diagnostic performance compared with planar V/Q scintigraphy and should be preferred when diagnosing PE.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Gutte et al. (2009) studied this question.

synapsesocial.com/papers/6a221be300d082f62f970be8https://doi.org/10.1097/mnm.0b013e3283336747
Ask AI
Helpful
Bookmark
Share
View Full Paper