PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 12, 2019AJP Heart and Circulatory Physiology6 citationsOpen Access

Intravenous ivabradine augments the dynamic heart rate response to moderate vagal nerve stimulation in anesthetized rats

TKToru KawadaHYHiromi YamamotoKUKazunori Uemura

Structured PICO

Does intravenous ivabradine modify the dynamic heart rate response to vagal nerve stimulation in anesthetized rats?

P
Population
Anesthetized Wistar-Kyoto rats (n=7)
I
Intervention
Intravenous ivabradine (2 mg/kg)
C
Comparator
Baseline state before intravenous administration of ivabradine
O
Outcome
Transfer function from efferent vagal nerve stimulation (VNS) to heart rate (HR), including asymptotic dynamic gain and corner frequencysurrogate

Ivabradine interacts with dynamic vagal heart rate control, augmenting the heart rate response to moderate-intensity efferent vagal nerve stimulation in a rat model.

Abstract

Ivabradine is a selective bradycardic agent that reduces the heart rate (HR) by inhibiting the hyperpolarization-activated cyclic nucleotide-gated channels. Although its cardiovascular effect is thought to be minimal except for inducing bradycardia, ivabradine could interact with cardiovascular regulation by the autonomic nervous system. We tested whether ivabradine modifies dynamic characteristics of peripheral vagal HR control. In anesthetized Wistar-Kyoto rats ( n = 7), the right vagal nerve was sectioned and stimulated for 10 min according to a binary white noise sequence with a switching interval of 500 ms. The efferent vagal nerve stimulation (VNS) trials were performed using three different rates (10, 20, and 40 Hz), and were designated as V 0–10 , V 0–20 , and V 0–40 , respectively. The transfer function from the VNS to the HR was estimated before and after the intravenous administration of ivabradine (2 mg/kg). Ivabradine increased the asymptotic dynamic gain in V 0–20 from 3.88 (1.78–5.79) to 6.62 (3.12–8.31) beats·min −1 ·Hz −1 , P < 0.01, median (range) but not in V 0–10 or V 0–40 . Ivabradine increased the corner frequency in V 0–10 from 0.032 (0.026–0.041) to 0.064 (0.029–0.090) Hz, P < 0.01 and V 0–20 from 0.040 (0.037–0.056) to 0.068 (0.051–0.100) Hz, P < 0.01 but not in V 0–40 . In conclusion, ivabradine augmented the dynamic HR response to moderate VNS. At high VNS, however, ivabradine did not significantly augment the dynamic HR response, possibly because ivabradine reduced the baseline HR and limited the range for the bradycardic response to high VNS. NEW & NOTEWORTHY Ivabradine is considered to be a pure bradycardic agent that has little effect on cardiovascular function except inducing bradycardia. The present study demonstrated that ivabradine interacts with the dynamic vagal heart rate control in a manner that augments the heart rate response to moderate-intensity efferent vagal nerve stimulation.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kawada et al. (2019) studied this question.

synapsesocial.com/papers/6a22843affccceb004b73a4chttps://doi.org/10.1152/ajpheart.00288.2019
Ask AI
Helpful
Bookmark
Share
View Full Paper