PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 2008IEEE Transactions on Industrial Electronics355 citations

Instantaneous Reactive Power Theory Applied to Active Power Filter Compensation: Different Approaches, Assessment, and Experimental Results

View Full Paper
RHReyes S. HerreraPRPatricio Salmerón RevueltaHKHyosung Kim

Key Points

Key points are not available for this paper at this time.

Abstract

In this paper, the five main formulations of the instantaneous reactive power theory have been chosen to study nonlinear load compensation. They are p - q original theory, d - q transformation, modified or cross-product formulation, p - q - r reference frame, and vectorial theory. The obtention of the compensation current according to each formulation has been established. Next, the behavior of an active power filter (APF) that is implemented with those different control algorithms has been studied. On one hand, a simulation platform with control, APF, and load has been built to test them. Results obtained in an unbalanced and nonsinusoidal three-phase four-wire system have been compared by means of the most adequate indexes. On the other hand, the APF control strategies have been implemented in an experimental platform constituted by a 20-kVA power inverter and a 400-MHz digital signal processing controller board. The final analysis shows that, in general, the five theories present a different behavior, which depends on supply voltage, with respect to distortion. However, all of them widely decrease the waveform distortion. Moreover, a more general compensation objective is possible. It obtains balanced and sinusoidal source current in any conditions of the supply voltage.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Herrera et al. (2008) studied this question.

synapsesocial.com/papers/6a22f9f4cf4af46152cb1ad7https://doi.org/10.1109/tie.2007.905959
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Digital Repetitive Control of a Three-Phase Four-Wire Shunt Active Filter2007 · 222 citations
  2. 2Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components1984 · 3,379 citations
  3. 3A New Compensation Method for High Current Non-Linear Loads2006 · 9 citations
  4. 4Instantaneous Reactive Power Theory to N Wire Systems2007 · 11 citations
  5. 5Active Filtering Function of Three-Phase PWM Boost Rectifier Under Different Line Voltage Conditions2005 · 137 citations