May 1, 2019IEEE Sensors Journal259 citations

Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review

View Full Paper
DBDwaipayan BiswasNSNeide Simões‐CapelaCHChris Van Hoof

Structured PICO

I
Intervention
Wrist-worn photoplethysmography (PPG) for heart rate estimation

This review provides a comprehensive overview of heart rate estimation using wrist-worn PPG, setting a platform for future research on pervasive monitoring.

Abstract

Photoplethysmography (PPG) is a low-cost, non-invasive, and optical technique used to detect blood volume changes in the microvascular tissue bed, measured from the skin surface. It has traditionally been used in commercial medical devices for oxygen saturation, blood pressure monitoring, and cardiac activity for assessing peripheral vascular disease and autonomic function. There has been a growing interest to incorporate PPG sensors in daily life, capable of use in ambulatory settings. However, inferring cardiac information (e.g. heart rate) from PPG traces in such situations is extremely challenging, because of interferences caused by motion. Following the IEEE Signal Processing Cup in 2015, numerous methods have been proposed for estimating particularly the average heart rate using wrist-worn PPG during physical activity. Details on PPG technology, sensor development, and applications have been well documented in the literature. Hence, in this paper, we have presented a comprehensive review of state-of-the-art research on heart rate estimation from wrist-worn PPG signals. Our review also encompasses brief theoretical details about PPG sensing and other potential applications-biometric identification, disease diagnosis using wrist PPG. This paper will set a platform for future research on pervasive monitoring using wrist PPG.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Biswas et al. (2019) studied this question.

synapsesocial.com/papers/6a23800a55bd20cf6fa5e587https://doi.org/10.1109/jsen.2019.2914166
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1A Short Study to Assess the Potential of Independent Component Analysis for Motion Artifact Separation in Wearable Pulse Oximeter Signals2005 · 82 citations
  2. 2Unveiling the Biometric Potential of Finger-Based ECG Signals2011 · 770 citations
  3. 3Motion Artifact Cancellation in Wearable Photoplethysmography Using Gyroscope2018 · 79 citations
  4. 4Validity and Reliability of the Apple Watch for Measuring Heart Rate During Exercise2017 · 95 citations
  5. 5Projections on the number of individuals with atrial fibrillation in the European Union, from 2000 to 20602013 · 1,446 citations