PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 6, 2026The Journal of Sexual Medicine0 citations

(461) Complex Management of Cylinder Coating Adhesion in Infrapubic Penile Prosthesis Revision Surgery

View Full Paper
GAG AntoniniEPE Pozzi

Key Points

  • The aim is to address the complications associated with cylinder coating adhesion during penile prosthesis revision surgeries.
  • Demonstrated a third-time revision case of a three-piece inflatable penile prosthesis in a 60-year-old male.
  • Utilized a lateral incision at the sub-glandular level for direct visualization and extraction of adherent material.
  • Performed reimplantation of a new device through the same infrapubic incision.
  • Successfully extracted the retained cylinder coating after managing severe adhesion.
  • Reimplantation was performed without complications noted in the surgical approach.
  • Hematoma prevention was ensured through the placement of two scrotal drains.

Abstract

Abstract The video demonstrates a challenging third-time revision case of a three-piece inflatable penile prosthesis in a 60-year-old male with a history of two previous inflatable penile prosthesis implantations (IPP) – the first using a peno-scrotal approach and the second using an infra-pubic approach. The current revision surgery is indicated due to mechanical failure of the most recent device, with additional consideration for the patient's dissatisfaction regarding both penile length and girth. The surgical approach highlights a rare but significant complication: severe adhesion of cylinder coating to the tunica albuginea, likely due to scarring of the previous surgeries. Using an infrapubic surgical access, the procedure showcases the step-by-step management of firmly adherent prosthetic material, with particular focus on the left corporal body where a challenging situation arose as the cylinder coating separated during extraction, leaving its distal portion firmly adhered to the tunica albuginea at the sub-glandular level. To address this retained material, we performed a lateral incision at the sub-glandular level, which provided direct visualization and allowed for complete extraction of the adherent cylinder coating. Following successful removal, reimplantation of a new three-piece device was performed through the same infrapubic incision, with reservoir placement in the space of Retzius. The video highlights the critical decision points, surgical steps, and technical challenges essential for managing such complicated IPP revisions. Lastly, careful attention to hematoma’s prevention is demonstrated via the placement of two scrotal drains. Disclosure No

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Antonini et al. (2026) studied this question.

synapsesocial.com/papers/6a23bafd71a5da9775e76895https://doi.org/10.1093/jsxmed/qdag118.405
Ask AI
Helpful
Bookmark
Share
View Full Paper