Update on the need for a permanent pacemaker after transcatheter aortic valve implantation using the CoreValve® Accutrak™ system

View Full Paper
DTDidier TchétchéTMThomas ModineBFBruno Farah

Key Result

Transcatheter aortic valve implantation using the CoreValve Accutrak system resulted in a permanent pacemaker implantation rate of 10.6%.

Study Design

Type

Cohort (n=134)

Multicenter

Yes

Structured PICO

Does the CoreValve Accutrak system improve positioning accuracy and reduce the need for permanent pacemaker implantation in patients undergoing TAVI?

P
Population
134 patients (mean age 82.4 years) treated with the CoreValve Accutrak system for transcatheter aortic valve implantation at two French centers.
E
Exposure
Transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve® Accutrak™ system (26 or 29 mm)
O
Outcome
Accuracy of positioning across the aortic annulus and need for a permanent pacemakersafety

The use of the CoreValve Accutrak system for TAVI resulted in a low permanent pacemaker implantation rate of 10.6%, likely due to a predictable and shallow implantation depth.

Limitations

  • Limited number of events prevented identification of predictors for permanent pacemaker need.
  • Limited number of events preventing identification of predictors for permanent pacemaker need

Abstract

AIMS: High rates of permanent pacemaker (PPM) implantation are reported after transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve® system. The Accutrak™ catheter is designed to allow a more predictable landing zone. Little is known about the real clinical impact of this catheter. The aims of this paper were to describe the potential impact of the Accutrak™ catheter on the accuracy of positioning a 26 or 29 mm CoreValve® across the aortic annulus and its impact on the need for a pacemaker. METHODS AND RESULTS: A total of 134 patients were treated with the CoreValve® Accutrak™ system at two French centres (Lille and Toulouse). Mean age was 82.4 ± 4.7 years; logistic EuroSCORE was 24.3 ± 9.5%. Procedural success rate was 99.2%; mean depth of implantation was 4.9 mm. A final position between 0 and 6 mm was achieved in 85.8% of the patients. All-cause mortality at 30 days was 6%. The PPM implantation rate was 10.6%. Due to a limited number of events, we could not identify any predictor of need for a PPM: pre-existing right bundle branch block (RBBB) (OR 2.72 0.63-11.87, p=ns), use of a 29 mm prosthesis (OR 2.73 0.33-22.90, p=ns) and left ventricular septal hypertrophy (OR 2.63 0.08-83.32, p=ns). CONCLUSIONS: In this cohort of patients treated with the CoreValve® Accutrak™ system, the incidence of permanent pacemaker implantation was low, which may be a consequence of an average small implantation depth. The Accutrak™ catheter seems to be helpful in achieving higher and more predictable implants. Operators could standardise their technique to place the CoreValve® prostheses less than 6 mm below the aortic annulus.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tchétché et al. (2012) conducted a cohort in Transcatheter aortic valve implantation (n=134). CoreValve Accutrak system was evaluated on Permanent pacemaker implantation. Transcatheter aortic valve implantation using the CoreValve Accutrak system resulted in a permanent pacemaker implantation rate of 10.6%.