February 1, 2023Diabetes Technology & Therapeutics54 citations

Expert Guidance on Off-Label Use of Hybrid Closed-Loop Therapy in Pregnancies Complicated by Diabetes

View Full Paper
ESEmily D. SzmuilowiczCLCarol J. LevyEBElizabeth Buschur

Key Points

Key points are not available for this paper at this time.

Abstract

Automated insulin delivery (AID) systems have established benefits in terms of glycemic control, health outcomes, and quality of life and are strongly recommended for people with type 1 diabetes outside of pregnancy. While evidence for use of investigational AID systems during pregnancy is promising, data and guidance are still needed regarding use of commercially available systems during pregnancy. Unfortunately, none of the hybrid closed-loop (HCL) systems that are currently available in the United States have glucose targets that are as aggressive as pregnancy glycemic targets, none have a pregnancy-specific algorithm, and none are approved for use during pregnancy. As such, any use of these systems during pregnancy is considered off-label in the United States and would be "assisted" by provider/user techniques. Despite these limitations, many women conceive while using clinically available HCL systems and may be hesitant to cease use during pregnancy. Achievement of strict pregnancy glycemic targets can be difficult, and it is conceivable that selective off-label use of clinically available HCL systems in some women could lead to improved glycemia. We herein offer expert guidance based on clinical experience and available case reports on how to identify appropriate candidates for HCL therapy in pregnancy, how to counsel pregnant women with diabetes on the potential risks and benefits of HCL therapy during pregnancy, and how to manage commercially available systems off-label throughout gestation in an assisted HCL approach.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Szmuilowicz et al. (2023) studied this question.

synapsesocial.com/papers/6a2b3dde888ed9a2d5c6b386https://doi.org/10.1089/dia.2022.0540
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Modeling Transient Disconnections and Compression Artifacts of Continuous Glucose Sensors2016 · 56 citations
  2. 2Effects of fat on carbohydrate absorption: more is not necessarily better2001 · 14 citations
  3. 3Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes2019 · 1,006 citations
  4. 4Continuous glucose monitoring targets in type 1 diabetes pregnancy: every 5% time in range matters2019 · 141 citations
  5. 5Commercialized Hybrid Closed-Loop System (Minimed Medtronic 670G) Results During Pregnancy2021 · 26 citations