PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 12, 2026Diagnostics0 citationsOpen Access

Safe Prostatic Artery Embolization with Cyanoacrylate: Representative Cases Demonstrating Non-Target Artery Preservation

View Full Paper
AVAntonio VizzusoASAntonio SpinaMBMaria Vittoria Bazzocchi

Key Points

  • This research aims to evaluate the technical advantages of n-butyl cyanoacrylate in prostatic artery embolization compared to standard methods.
  • Five cases of prostatic artery embolization were performed using n-butyl cyanoacrylate under fluoroscopy.
  • NBCA mixed with iodized oil was injected in small aliquots using a blocked-flow technique to ensure non-target artery preservation.
  • The intervention focused on protecting the penile artery while adequately managing complex pelvic vascular anatomy.
  • NBCA allowed for precise control of embolization through unique mechanisms, avoiding the need for protective coiling.
  • All procedures demonstrated effective preservation of non-target arteries, enhancing the safety profile of the intervention.
  • Glue-based PAE was found to be a reproducible and efficient alternative to particulate embolization in anatomically complex cases.

Abstract

This study describes five case of prostatic artery embolization (PAE) using n-butyl cyanoacrylate methylsulfone (NBCA; Glubran 2, GEM; Viareggio, Italy) to evaluate its technical advantages, against standard particulate embolization, in managing complex pelvic vascular anatomy while preserving non-target arteries, with particular focus on penile artery protection. NBCA was mixed with iodized oil (Lipiodol Ultra Fluid; Guerbet, Aulnay-sous-Bois, France) at 1:5 dilution and injected in small aliquots (0.1–0.3 mL) under fluoroscopy using a blocked-flow technique, with injection stopped at reflux into the horizontal PA segment. After a few seconds, before the complete polymerization of the glue, the microcatheter is quickly withdrawn, flushed, and reused for the contralateral side. NBCA allowed precise embolic control through distinct mechanisms (direct distal, indirect distal, proximal, reflux and controlateral control), avoiding the need for protective coiling. Glue-based PAE seems a reproducible, safe, and efficient alternative to particulate embolization, offering enhanced embolization control and non-target artery preservation in anatomically complex patients.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Vizzuso et al. (2026) studied this question.

synapsesocial.com/papers/6a2ba2448101cf8926f01415https://doi.org/10.3390/diagnostics16121785
Ask AI
Helpful
Bookmark
Share
View Full Paper