PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 30, 2010Current Medical Research and Opinion108 citations

Comparative glycemic control, safety and patient ratings for a new 4 mm × 32G insulin pen needle in adults with diabetes

View Full Paper
LHLaurence HirschMGMichael A. GibneyJAJohn Albanese

Key Points

Key points are not available for this paper at this time.

Abstract

OBJECTIVE: Pen needles (PN) for subcutaneous insulin therapy have become smaller; 5 mm PNs are now the shortest in use. We evaluated the safety, efficacy and patient ratings of a new 4 mm x 32 gauge (G) PN. RESEARCH DESIGN AND METHODS: Subjects with type 1 and type 2 diabetes and HbA1c 5.5% to 9.5% participated in a randomized non-inferiority cross-over trial, at four U.S. centers. Subjects used 4 mm x 32G PNs and either 5 mm x 31G PNs (4/5 mm) or 8 mm x 31G PNs (4/8 mm) in two, 3-week treatment periods; order of needle use was controlled. Subjects were either 'low dose' or 'regular dose' users (highest single insulin dose <or= 20 units and 21-40 units, respectively). Percent absolute change in serum fructosamine (% |Delta Fru|) was the primary endpoint; unexplained, severe hypo- or hyperglycemia was a secondary measure. Leakage at injection sites and pain measured by visual analog scale were tertiary measures. Equivalent glycemic control was defined á priori as % |Delta Fru| (including 95% CI) within 20%; 40 subjects per subgroup provides 90% power at alpha = 0.05. CLINICAL TRIAL REGISTRATION: The study was registered on clinicaltrials.gov (identifier: NCT00928057). RESULTS: Of 173 subjects randomized, 168 completed the study, and 163 were included in the fructosamine analyses--83 and 80 in the 4/5 mm and 4/8 mm groups, respectively. Subjects were 56% male, mean 52.6 yrs, 63% type 2. Baseline HbA1c = 7.5 +/- 1.0% and fructosamine 301 +/- 55.1 micromol/L. Mean % |Delta Fru| was 4.9% (95% CI 3.8, 6.0) and 5.5% (4.5, 6.4), respectively, for the 4/5 mm and 4/8 mm groups, meeting glycemic equivalence criteria; results were similar in both dose groups. The median |Delta Fru| was 11.0 micromol/L (8.0, 13.0) and 13.5 micromol/L (9.8, 18.0) for the 4/5 mm and 4/8 mm groups, respectively. Unexplained, severe hypo- and hyperglycemic episodes were infrequent and not different between PNs. The 4 mm PN was rated significantly less painful and preferred by approximately 2/3 of subjects (p < 0.01). All three PNs had similar reported injection site leakage. LIMITATIONS: The study was of relatively short duration, in adults in the U.S. Further trials in other patients (e.g., GLP-1 users, pediatrics, obese) should be performed. CONCLUSIONS: The 4 mm x 32G PN provided equivalent glycemic control compared to 31G, 5 mm and 8 mm PNs with reduced pain, no difference in insulin leakage and was preferred by patients.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hirsch et al. (2010) studied this question.

synapsesocial.com/papers/6a3292eeaaf0ec54eae499afhttps://doi.org/10.1185/03007995.2010.482499
Ask AI
Helpful
Bookmark
Share
View Full Paper