PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 19, 2026Analytical Chemistry0 citationsOpen Access

Preanalytical Workflow Establishment for Reproducible Clinical Blood-Based Infrared Molecular Fingerprinting

View Full Paper
KDKatharina DietmannGGGuanting GuoJAJacqueline Aschauer

Key Points

  • The aim is to systematically evaluate how preanalytical variables affect infrared molecular fingerprinting of blood samples.
  • Investigated preanalytical variables including blood draw tube types, fill volumes, delay times before centrifugation, and freeze-thaw cycles.
  • Utilized Fourier transform infrared spectroscopy for molecular analysis of blood serum and plasma samples.
  • Applied multivariate analysis and machine learning to assess the effects of technical parameters on fingerprinting.
  • Identified that specific conditions, such as tube type and delay times, significantly altered infrared fingerprints.
  • Parameter-related spectral variation was found to be smaller than intrinsic biological variability.
  • Demonstrated that harmonizing preanalytical workflows can improve reproducibility and study comparability.

Abstract

Standardized preanalytical sample handling is a cornerstone of reliable molecular analytics, particularly where subtle multimolecular differences can drive biological interpretation. In different clinical studies, blood-based samples are often processed using varying workflows, and the influence of individual technical parameters remains poorly quantified. In particular, preanalytical differences can limit study comparability and complicate the robust evaluation of the approach for different applications and specific medical questions. Here, we systematically investigate the effects of major preanalytical variables on infrared molecular fingerprinting (IMF) of blood serum and plasma, performed via Fourier transform infrared (FTIR) spectroscopy. We examine the impacts of venous blood draw tube types, tube fill volumes, delay times prior to centrifugation, centrifugation conditions, freezing and thawing procedures, and delay times between final sample preparation and infrared spectroscopy. We found that the type of blood collection tube, the fill volume of the tube, a delay of more than 4 h before centrifugation, more than two freeze-thaw cycles, and delays prior to measurement can result in systematic changes in infrared fingerprints that are detectable through multivariate analysis and machine learning. Importantly, for most conditions, the magnitude of parameter-related spectral variation remains smaller than the intrinsic biological variability across individuals, supporting the feasibility of IMF for realistic clinical settings. The presented results provide actionable guidance and a basis for harmonizing preanalytical workflows, reducing preanalytical confounding in IMF-based biofluid analysis, and improving cross-study comparability, with relevance that may generalize to other molecular profiling technologies, clinical studies, and biobanking.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Dietmann et al. (2026) studied this question.

synapsesocial.com/papers/6a34dec865a5b0777af2e096https://doi.org/10.1021/acs.analchem.6c01358
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Stability of person-specific blood-based infrared molecular fingerprints opens up prospects for health monitoring2021 · 80 citations
  2. 2Amyloid blood biomarker detects Alzheimer's disease2018 · 189 citations
  3. 3Longitudinal multi-omics of host–microbe dynamics in prediabetes2019 · 622 citations
  4. 4The UK Biobank sample handling and storage protocol for the collection, processing and archiving of human blood and urine2008 · 1,047 citations
  5. 5Controlling pre-analytical process in human serum/plasma metabolomics2023 · 17 citations