PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 20, 2026European Heart Journal31 citations

Influence of negative intrathoracic pressure on right atrial and systemic venous dynamics

View Full Paper
JVJuha VirolainenMVMarkku VentiläHTHeikki Turto

Key Points

  • This research aims to determine how a decrease in intrathoracic pressure affects blood flow in the right heart and systemic venous circulation.
  • 16 patients were studied using thermodilution and cinevenograms.
  • Measurements included simultaneous pressure recordings with two micromanometric transducers during graded Mueller manoeuvres.
  • Drop in airway pressure was assessed, and changes in right atrial pressure and inferior vena cava diameter were recorded.
  • Right atrial mean pressure decreased by 17 mmHg during the lesser manoeuvre and 38 mmHg during the greater (P < 0.003).
  • Internal jugular venous pressure decreased significantly by 16 mmHg (P < 0.03) and 24 mmHg (P < 0.03).
  • The minimum diameter of the inferior vena cava decreased by 69% during the greater manoeuvre (P = 0.002).

Abstract

To investigate the effect of a sustained fall in intrathoracic pressure (Mueller manoeuvre) on blood flow through the right heart and on systemic venous dynamics, 16 patients were studied using thermodilution, cinevenograms and simultaneous pressure recordings with two micromanometric transducers. The reductions in airway pressure (median range) during two graded Mueller manoeuvres were 25 (20-30) and 42 (22-52) mmHg. Right atrial mean pressure decreased by 17 (2-25) mmHg during the former and 38 (0-49) mmHg during the latter, and simultaneously, pressure gradients of 23 (1-32) and 45 (1-82) mmHg developed between the inferior vena cava and right atrium (P < 0.003 for all). Internal jugular venous pressure decreased by 16 (4-25) and 24 (4-43) mmHg (P < 0.03 for both), respectively, and no pressure gradient developed between internal jugular and superior caval veins. The minimum diameter of the proximal inferior vena cava decreased by 69 (-49-84)% (P = 0.002) during the greater manoeuvre. Cardiac index tended to increase by 26 (-17-40)% (P < 0.066) during the lesser manoeuvre but did not change statistically significantly during the greater. In conclusion, during negative intrathoracic pressure caused acutely by the Mueller manoeuvre, right atrial pressure decreases and the inferior vena cava collapses partially at or below the diaphragm. Despite a significant venous obstruction between the lower body and right atrium, blood flow through the right heart increases or remains constant.