PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 21, 2026Sports Biomechanics0 citations

Validity of using a smartphone-based markerless motion capture system for quantitative analysis of human dynamic movements

View Full Paper
HLHuaqing LiangCGCurtis Justin GrantYBYekaterina Bolgarskaya

Key Points

  • This study evaluates the accuracy of a smartphone-based markerless motion capture system for analyzing human dynamic movements compared to traditional systems.
  • Participants (N=41) performed movements including walking, running, jumping, and cutting.
  • Simultaneous dual-system capture was employed to assess lower-extremity joint kinematics.
  • Kinematic agreement was evaluated using metrics such as RMSE, NRMSE, Pearson’s r, and Statistical Parametric Mapping.
  • OpenCap showed strong sagittal-plane agreement with RMSE of 7.0°–13.4° and NRMSE of 7.4%–24.5%.
  • Out-of-plane kinematics exhibited high errors with RMSE of 3.5°–16.6% and variable correlations (r = –0.09–0.80).
  • OpenCap performed better in spatially constrained tasks than expansive movements, revealing algorithmic challenges.

Abstract

Quantitative motion analysis is often restricted in clinical and sports settings due to high cost and technical requirements of 3D optical systems (MoCap). This study assessed the validity of a smartphone-based markerless system (OpenCap) against MoCap across eight dynamic tasks. Participants (N = 41) performed movements including walking, running, jumping, and cutting, with simultaneous dual-system capture. Lower-extremity joint kinematic agreement was evaluated using discrete metrics (Root-Mean-Square-Error RMSE, normalised RMSE NRMSE, Pearson’s r, and Bland-Altman analyses) and continuous Statistical Parametric Mapping (SPM). OpenCap demonstrated strong sagittal-plane agreement (RMSE = 7.0°–13.4°, NRMSE = 7.4%–24.5%, r = 0.70–0.99) and similar SPM waveforms, despite systematically overestimating flexion/dorsiflexion by 5°–15°. Conversely, out-of-plane kinematics exhibited high normalised errors (RMSE = 3.5°–16.6°, NRMSE = 29.0%–136.3%), highly variable correlations (r = –0.09–0.80), and divergent SPM waveforms. Additionally, OpenCap performed generally better during spatially constrained jumping movements than expansive translating tasks. This highlights algorithmic challenges regarding temporal synchronisation and distal tracking when individuals translate rapidly across the cameras’ depth of field. While OpenCap currently lacks the multi-planar precision necessary for absolute out-of-plane evaluation, it successfully captures overarching sagittal trajectories. Ultimately, users must carefully weigh the system’s accessibility advantages against its kinematic limitations before implementation in field or clinical environments.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Liang et al. (2026) studied this question.

synapsesocial.com/papers/6a377edf24f042ddf4c59c2ehttps://doi.org/10.1080/14763141.2026.2689518
Ask AI
Helpful
Bookmark
Share
View Full Paper