Design and Optimization of a Multi-Aperture Rebuncher Model Cavity for High Current Neutron Sources

View Full Paper
WLWeiming LiXZXin ZhuoBWBaichuan Wang

Key Points

  • The aim is to design a multi-aperture focusing chamber to enhance beam compression and increase peak current.
  • Geometrically heterogeneous design based on traditional QWR chamber
  • Analytical calculations using coaxial line theory and modified formulas
  • Electromagnetic design optimization through parameter sweeps using simulation software.
  • Operates at a frequency of 81.25 MHz with a branch impedance of 5.62 MΩ
  • Q-factor measured at 14,734.2, power dissipation at 1.78 kW, and Kilpatrick factor at 0.51
  • Significant beam focusing achieved without loss and minimal impact from transverse field and phase jitter errors.

Abstract

Path modulation is an effective method for increasing the peak beam current. To maintain the longitudinal structure of the compressed beam, a multi-aperture focusing chamber capable of simultaneously focusing multiple beam bunches must be placed at the symmetrical point of the beam compression system. This paper presents a geometrically heterogeneous design based on a conventional QWR chamber and performs analytical calculations using coaxial line theory and modified formulas. By adjusting certain geometric parameters of the chamber, the voltage deviation in the accelerating gap is controlled within 1%. Simulation software was used to perform parameter sweeps for electromagnetic design optimization, and the high-frequency parameters of the cavity were calculated for both the empty cavity and configurations with tuners of different radii. The results indicate that the cavity operates at a frequency of 81.25 MHz, with a branch impedance of 5.62 MΩ, a Q-factor of 14,734.2, a power dissipation of 1.78 kW, and a Kilpatrick factor of 0.51. Simulation results of the beam dynamics using the PIC program show that the cavity exhibits significant beam focusing with no beam loss; the presence of errors such as transverse field and beam phase jitter has no significant effect on the beam compression performance.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Li et al. (2026) studied this question.

synapsesocial.com/papers/6a377fdd24f042ddf4c5a2e0https://doi.org/10.1016/j.net.2026.104506
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Beam dynamics study of the high-power electron beam irradiator using niobium-tin superconducting cavity2024
  2. 2Research on the compact design of bunching cavities for high modulation depth of intense-current relativistic electron beams2025
  3. 3Proposal and design of three types of novel multi-beam IH-RFQs for ion implantation2026
  4. 4Field tuning study and RF electromagnetic design of a continuous-wave RFQ with ramped inter-vane voltage for AB-BNCT2024 · 2 citations
  5. 5Design and low-power measurement of the broadband kicker cavity used to compensate the transient beam-loading effect in synchrotron light sources2025