December 11, 2020Circulation Arrhythmia and Electrophysiology60 citationsOpen Access

Anatomical Predictors of Pacemaker Dependency After Transcatheter Aortic Valve Replacement

View Full Paper
LFLuca Nai FovinoACAlberto CiprianiTFTommaso Fabris

Key Result

A difference between membranous septum length and implantation depth ≥3 mm was strongly associated with 30-day pacemaker dependency after TAVR (OR 7.58; 95% CI 2.07-27.78; P=0.002).

Study Design

Type

Cohort (n=112)

Structured PICO

Do specific anatomical factors predict pacemaker dependency in patients undergoing pacemaker implantation after TAVR?

P
Population
112 patients (median age 81, 46.5% female) undergoing pacemaker implantation up to 30 days after TAVR, followed for a median of 28.1 months.
E
Exposure
Assessment of anatomical predictors including left ventricular outflow tract (LVOT) calcifications and the difference between membranous septum length and implantation depth (ΔMSID).
O
Outcome
Pacemaker dependency at 30 days and 1 yearsafety

Less than half of patients requiring a pacemaker after TAVR remain pacemaker-dependent at midterm follow-up, and anatomical factors such as ΔMSID ≥3 mm and LVOT calcifications can help predict long-term dependency.

Main Result

Odds Ratio: 7.58 (95% CI 2.07–27.78)

p-value: p=0.002

Abstract

Background: Conduction disturbances after transcatheter aortic valve replacement (TAVR) are often transient. Limited data exist on anatomic factors predisposing to pacemaker dependency after TAVR. We sought to assess the rate and the possible predictors of pacemaker dependency after TAVR. Methods: Consecutive patients undergoing pacemaker implantation up to 30 days after TAVR between May 2014 and September 2019 were included. Baseline electrocardiographic, computed tomography, and procedural characteristics were collected, including valve implantation depth and membranous septum length, an anatomic surrogate of the distance between the aortic annulus and the His bundle. Pacemaker dependency at 30 days and 1 year and all-cause mortality during follow-up were evaluated. Results: Of 728 TAVR patients, 112 (53.5% men; median age, 81 years) underwent pacemaker implantation after TAVR. Of these, 44.6% (50 of 112) were pacemaker dependent at 30 days and 46.7% (36 of 77) at 1 year. By multivariate analysis, independent predictors of 30-day pacemaker dependency included left ventricular outflow tract calcifications under the left coronary cusp (odds ratio, 5.69 95% CI, 1.45–22.31; P =0.013) and a difference between membranous septum length and implantation depth (ΔMSID) ≥3 mm (odds ratio, 7.58 95% CI, 2.07–27.78; P =0.002). Conversely, membranous septum length and implantation depth alone were not associated with pacemaker dependency (odds ratio, 0.79 95% CI, 0.60–1.05; P =0.11 and odds ratio, 1.11 95% CI, 0.99–1.24; P =0.08). At a median follow-up of 28.1 (11.7–48.6) months, pacemaker-dependent patients did not show a worse survival ( P =0.26). Conclusions: Less than half of the patients undergoing pacemaker implantation after TAVR are pacemaker-dependent at midterm follow-up. ΔMSID ≥3 mm and the presence of left ventricular outflow tract calcifications under the left coronary cusp, but not membranous septum length nor implantation depth alone, are predictive of long-term pacemaker dependency after TAVR, thus influencing device selection and programming.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Fovino et al. (2020) conducted a cohort in Pacemaker dependency after TAVR (n=112). Difference between membranous septum length and implantation depth (ΔMSID) ≥3 mm vs. ΔMSID <3 mm was evaluated on 30-day pacemaker dependency (OR 7.58, 95% CI 2.07-27.78, p=0.002). A difference between membranous septum length and implantation depth ≥3 mm was strongly associated with 30-day pacemaker dependency after TAVR (OR 7.58; 95% CI 2.07-27.78; P=0.002).

synapsesocial.com/papers/6a3ef4561ec12ccad408d5bchttps://doi.org/10.1161/circep.120.009028
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Electrocardiographic Predictors of Long‐Term Cardiac Pacing Dependency Following Transcatheter Aortic Valve Implantation2016 · 50 citations
  2. 2Pacemaker dependency after transcatheter aortic valve implantation: incidence, predictors and long-term outcomes2019 · 109 citations
  3. 3The interplay between permanent pacemaker implantation and mortality in patients treated by transcatheter aortic valve implantation: A systematic review and meta‐analysis2018 · 30 citations
  4. 4Incidence and feasibility of coronary access after transcatheter aortic valve replacement2020 · 67 citations
  5. 5Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients2019 · 4,860 citations