Tender X-ray Coherence Characterization at Beamline BM44 of the High Energy Photon Source

View Full Paper
YWYongyang WangSLShuhu LiuKTKun Tang

Key Points

  • This research aims to characterize the spatial coherence of tender X-ray radiation using different methods.
  • Characterization conducted using a non-redundant array (NRA) of slits for measuring coherence.
  • Results verified through Young's double-slit experiment.
  • Comparison and analysis of coherence lengths obtained from both techniques.
  • Measured vertical coherence length using NRA method is 12.1±0.7μm.
  • Coherence length from Young’s double-slit experiment is 14.4±0.6μm.
  • Results indicate slight variations in coherence length between the two methods.

Abstract

High Resolution Image Download MS PowerPoint Slide A method for characterizing the spatial coherence of tender X-ray radiation using a single diffraction pattern is presented. The technique is based on scattering from a non-redundant array (NRA) of slits. It is used to measure the degree of spatial coherence at beamline BM44 (Tender X-ray Beamline) of the High Energy Photon Source. To verify the results, a Young’s double-slit experiment was also performed. This paper reports the coherence lengths obtained using both methods and provides a comparison and analysis of the two approaches. For the Tender X-ray Beamline, the measured vertical coherence length is 12.1±0.7μm using the NRA method, compared to 14.4±0.6μm derived from the Young’s double-slit experiment.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wang et al. (2026) studied this question.

synapsesocial.com/papers/6a420b08f91bb43ea9192272https://doi.org/10.1021/photonsci.6c00019
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Large-scale uniform Au nanodisk arrays fabricated via x-ray interference lithography for reproducible and sensitive SERS substrate2014 · 72 citations
  2. 2Nanosecond X-Ray Photon Correlation Spectroscopy on Magnetic Skyrmions2017 · 75 citations
  3. 3X-ray ptychography2017 · 685 citations
  4. 4Commissioning of the Tender X-ray Beamline at the High Energy Photon Source2025 · 1 citations
  5. 5Powerful scriptable ray tracing package xrt2014 · 57 citations