PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
December 5, 2022Scientific Reports44 citationsOpen Access

A fully-automated paper ECG digitisation algorithm using deep learning

HWHuiyi WuKPKiran Haresh Kumar PatelXLXinyang Li

Key Result

The fully-automated ECG digitisation algorithm achieved 99.0% correlation with ground truth digital signals for standard 3-by-4 ECGs without lead signal overlap.

Structured PICO

P
Population
1,376 12-lead ECGs in various configurations (3x4, 12x1, 3x1) from patients at two international centers used to validate an automated digitisation algorithm.
I
Intervention
Fully-automated online ECG digitisation tool using deep learning
C
Comparator
Ground truth digital ECG signals
O
Outcome
Correlation between the digitised signals and the ground truth ECGsurrogate

A fully-automated ECG digitisation tool successfully converts scanned paper ECGs into digital signals with high correlation to ground truth, facilitating large-scale deep learning projects.

Main Result

Effect estimate: 99.0% correlation

p-value: p=<0.001

Limitations

  • The text recognition model was trained on generic images and may not always recognize lead names on printed ECGs, particularly if obscured by large voltage signals or in low-resolution images.
  • Signal extraction may not be accurate in instances where there are overlapping ECG traces.

Abstract

There is increasing focus on applying deep learning methods to electrocardiograms (ECGs), with recent studies showing that neural networks (NNs) can predict future heart failure or atrial fibrillation from the ECG alone. However, large numbers of ECGs are needed to train NNs, and many ECGs are currently only in paper format, which are not suitable for NN training. We developed a fully-automated online ECG digitisation tool to convert scanned paper ECGs into digital signals. Using automated horizontal and vertical anchor point detection, the algorithm automatically segments the ECG image into separate images for the 12 leads and a dynamical morphological algorithm is then applied to extract the signal of interest. We then validated the performance of the algorithm on 515 digital ECGs, of which 45 were printed, scanned and redigitised. The automated digitisation tool achieved 99.0% correlation between the digitised signals and the ground truth ECG (n = 515 standard 3-by-4 ECGs) after excluding ECGs with overlap of lead signals. Without exclusion, the performance of average correlation was from 90 to 97% across the leads on all 3-by-4 ECGs. There was a 97% correlation for 12-by-1 and 3-by-1 ECG formats after excluding ECGs with overlap of lead signals. Without exclusion, the average correlation of some leads in 12-by-1 ECGs was 60-70% and the average correlation of 3-by-1 ECGs achieved 80-90%. ECGs that were printed, scanned, and redigitised, our tool achieved 96% correlation with the original signals. We have developed and validated a fully-automated, user-friendly, online ECG digitisation tool. Unlike other available tools, this does not require any manual segmentation of ECG signals. Our tool can facilitate the rapid and automated digitisation of large repositories of paper ECGs to allow them to be used for deep learning projects.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wu et al. (2022) studied Electrocardiogram digitisation (n=1,376). Fully-automated paper ECG digitisation algorithm vs. Ground truth digital ECGs was evaluated on Pearson's correlation between digitised signals and ground truth ECG (3x4 format without overlap) (99.0% correlation, p=<0.001). The fully-automated ECG digitisation algorithm achieved 99.0% correlation with ground truth digital signals for standard 3-by-4 ECGs without lead signal overlap.