July 12, 2026Acta Microbiologica Hellenica0 citationsOpen Access

A Retrospective Study of Neurosurgical Device-Related Infections over a Two-Year Period in a Tertiary Hellenic Setting

KAKalliopi AvgouleaASAndronikos SpyrouEKEmmanouella Kalogianni

Key Points

  • To examine the microbiological and clinical characteristics of CNS infections associated with neurosurgical devices.
  • Retrospective analysis of CSF samples from neurosurgery patients (August 2022–July 2024)
  • Microbial identification and susceptibility testing performed using VITEK-2 and broth microdilution
  • Infections defined per IDSA guidelines with outcomes based on therapeutic intervention.
  • Out of 825 CSF samples, 178 showed microbial growth (21.5%) with 102 patients involved.
  • Neurosurgical devices implanted in 68 patients with 29 developing CNS infections, attributed mainly to drains (72%).
  • 40 pathogens isolated; predominant were Acinetobacter baumannii (40%) and Klebsiella pneumoniae (12.5%).

Abstract

Neurosurgical devices provide clinical benefits that are undermined by the incidence of device-related infections. This study examined the microbiological and clinical characteristics of central nervous system (CNS) infections associated with cerebrospinal fluid (CSF) shunts and drains in neurosurgery patients during August 2022–July 2024. Upon suspicion of CNS infection, CSF samples were submitted for cytology, biochemical analysis, and culture. Identification and susceptibility testing were performed by VITEK-2 and VITEK-MS PRIME (bioMérieux); susceptibility to colistin was determined by broth microdilution (Bruker). The results were interpreted according to EUCAST guidelines. An infection definition was based on IDSA’s guidelines, and the outcome was considered positive upon successful therapeutic intervention. Out of 825 CSFs, 178 showed microbial growth in culture; they corresponded to 102 patients. Neurosurgical devices were implanted in 68 patients and, among them, 29 presented with a CNS infection. The infections attributed to drains and shunts were 72% versus 28%, respectively. Polymicrobial or consecutive infections occurred in 6/29 patients. Overall, 40 pathogens were isolated. The predominant causative agents were Acinetobacter baumannii (40%), Klebsiella pneumoniae (12.5%), coagulase-negative-Staphylococci (12.5%), and Pseudomonas aeruginosa (10%). Neurosurgical devices are easily contaminated and may cause CNS infections, regardless of the device type. The infections’ outcome is multifactorial; timely diagnosis and intervention are of utmost importance.