PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 18, 2019Journal of Nuclear Medicine67 citationsOpen Access

Image Quality and Activity Optimization in Oncologic 18F-FDG PET Using the Digital Biograph Vision PET/CT System

JSJoyce van SluisRBRonald BoellaardRDRudi Dierckx

Key Points

Key points are not available for this paper at this time.

Abstract

The first Biograph Vision PET/CT system (Siemens Healthineers) was installed at the University Medical Center Groningen. Improved performance of this system could allow for a reduction in activity administration or scan duration. This study evaluated the effects of reduced scan duration in oncologic 18F-FDG PET imaging on quantitative and subjective imaging parameters and its influence on clinical image interpretation. Methods: Patients referred for a clinical PET/CT scan were enrolled in this study, received a weight-based 18F-FDG injected activity, and underwent list-mode PET acquisition at 180 s per bed position (s/bp). Acquired PET data were reconstructed using the vendor-recommended clinical reconstruction protocol (hereafter referred to as “clinical”), using the clinical protocol with additional 2-mm gaussian filtering (hereafter referred to as “clinical+G2”), and—in conformance with European Association of Nuclear Medicine Research Ltd. (EARL) specifications—using different scan durations per bed position (180, 120, 60, 30, and 10 s). Reconstructed images were quantitatively assessed for comparison of SUVs and noise. In addition, clinically reconstructed images were qualitatively evaluated by 3 nuclear medicine physicians. Results: In total, 30 oncologic patients (22 men, 8 women; age: 48–88 y range, 67 ± 9.6 y mean ± SD) received a single weight-based (3 MBq/kg) 18F-FDG injected activity (weight: 45–123 kg range, 81 ± 15 kg mean ± SD; activity: 135–380 MBq range, 241 ± 47.3 MBq mean ± SD). Significant differences in lesion SUVmax were found between the 180-s/bp images and the 30- and 10-s/bp images reconstructed using the clinical protocols, whereas no differences were found in lesion SUVpeak. EARL-compliant images did not show differences in lesion SUVmax or SUVpeak between scan durations. Quantitative parameters showed minimal deviation (∼5%) in the 60-s/bp images. Therefore, further subjective image quality assessment was conducted using the 60-s/bp images. Qualitative assessment revealed the influence of personal preference on physicians’ willingness to adopt the 60-s/bp images in clinical practice. Although quantitative PET parameters differed minimally, an increase in noise was observed. Conclusion: With the Biograph Vision PET/CT system for oncologic 18F-FDG imaging, scan duration or activity administration could be reduced by a factor of 3 or more with the use of the clinical+G2 or the EARL-compliant reconstruction protocol.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Sluis et al. (2019) studied this question.

synapsesocial.com/papers/6a5d22993ce08021578a2888https://doi.org/10.2967/jnumed.119.234351
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Performance Characteristics of the Digital Biograph Vision PET/CT System2019 · 498 citations
  2. 2Image Quality and Diagnostic Performance of a Digital PET Prototype in Patients with Oncologic Diseases: Initial Experience and Comparison with Analog PET2015 · 154 citations
  3. 3Dual-Modality Imaging: Combining Anatomy and Function2008 · 284 citations
  4. 4The Netherlands protocol for standardisation and quantification of FDG whole body PET studies in multi-centre trials2008 · 397 citations
  5. 5Recent Advances and Future Progress in PET Instrumentation2015 · 183 citations