PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 9, 2009Clinical Orthopaedics and Related Research142 citations

Trabecular Metal™ Cups for Acetabular Defects With 50% or Less Host Bone Contact

View Full Paper
DLDror LaksteinTel Aviv UniversityDBDavid BacksteinNaples Community Hospital Healthcare SystemOSOleg SafirSinai Health System

Key Points

Key points are not available for this paper at this time.

Abstract

Acetabular component revision in the context of large contained bone defects with less than 50% host bone contact traditionally have been treated with roof reinforcement or antiprotrusio cages. Trabecular Metal cups (Zimmer, Inc, Warsaw, IN) may offer a reasonable treatment alternative. We evaluated the clinical and radiographic outcome of this mode of treatment. We prospectively followed 53 hip revision acetabular arthroplasty procedures performed with Trabecular Metal cups for contained defects with 50% or less contact with native bone. All patients were clinically and radiographically evaluated for evidence of loosening or failure. Minimum followup was 24 months (average, 45 months; range, 24-71 months). Contact with host bone ranged from 0% to 50% (average, 19%). The mean postoperative Merle d'Aubigne-Postel score was 10.6 (range, 1-12), with a mean improvement of 5.2 (range, -4-10) compared to the preoperative score. Two failed cups (4%) were revised. Two additional cups (4%) had radiographic evidence of probable loosening. Complications included four dislocations and one sciatic nerve palsy. The data suggest treatment of cavitary defects with less than 50% host bone contact using Trabecular Metal cups, without structural support by augments or structural bone grafts, is a reasonable option.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Lakstein et al. (2009) studied this question.

synapsesocial.com/papers/6a5dc1e47c4751fed08a2142https://doi.org/10.1007/s11999-009-0772-3
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Management of Periacetabular Bone Loss in Revision Hip Arthroplasty2007 · 61 citations
  2. 2Modified sliding trochanteric osteotomy in revision total hip arthroplasty2004 · 42 citations
  3. 3Acetabular Preparation in Cementless Revision TotaI Hip Arthroplasty1988 · 59 citations
  4. 4Radiological demarcation of cemented sockets in total hip replacement.1977 · 995 citations
  5. 5Radiological Demarcation of Cemented Sockets in Total Hip Replacement2013 · 2,522 citations