PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
October 1, 1998British Journal of Pharmacology125 citationsOpen Access

Disruption of synchronous gamma oscillations in the rat hippocampal slice: A common mechanism of anaesthetic drug action

View Full Paper
HFHoward J. FaulknerRTRoger D. TraubMWMiles A. Whittington

Key Points

Key points are not available for this paper at this time.

Abstract

At the molecular level much progress has been made towards elucidating the mechanisms of action of general and dissociative anaesthetics. However, little is known about how these molecular actions may lead to disruption of cognitive function. 2. A promising physiological correlate of cognitive function is the ability of spatially separate areas of the brain to synchronize firing patterns via mutual inhibitory, gamma-frequency (20-80 Hz) electrical oscillations. Here we examine the effects of five different anaesthetic/hypnotic agents with different primary mechanisms of action on these oscillations in the hippocampus. 3. Gamma oscillations were elicited simultaneously at two sites at either end of area CAI by tetanic stimulation. Such oscillations are synchronous between these areas even when separated by up to c. 4 mm in control conditions. 4. Agents which act directly on GABA(A) receptor-mediated inhibition had different effects on synchronous gamma oscillations. Thiopental (10-200 microm) markedly disrupted the oscillation and resulting synchrony whereas the benzodiazepines diazepam and temazepam (0.05-1.0 microM) had little effect. 5. The opiate morphine (10-200 microM) and dissociative agent ketamine (10-100 microM) had a different profile of effects on gamma oscillations. However, as with thiopental, both agents markedly disrupted between site synchrony. These three agents demonstrated this effect at aqueous concentrations relevant to anaesthetic ED50. 6. Using the hippocampus as a model neuronal network we propose that, despite differing primary mechanisms of action, anaesthetics may disrupt cognitive function by interfering with the mechanism of generation of synchronous firing patterns between spatially separate areas of the brain.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Faulkner et al. (1998) studied this question.

synapsesocial.com/papers/6a64d2f3e477a6b244644279https://doi.org/10.1038/sj.bjp.0702113
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Morphine disrupts long-range synchrony of gamma oscillations in hippocampal slices1998 · 82 citations
  2. 2EFFECTS OF KETAMINE AND OF HIGH PRESSURE ON THE RESPONSES TO γ‐AMINOBUTYRIC ACID OF THE RAT SUPERIOR CERVICAL GANGLION in vitro1982 · 19 citations
  3. 3Ketamine increases the amplitude of the 40-Hz auditory steady-state response in humans1997 · 125 citations
  4. 4Anesthetic Effects on Resting Membrane Potential Are Voltage-dependent and Agent-specific1991 · 61 citations
  5. 5The dissociative anaesthetics, ketamine and phencyclidine, selectively reduce excitation of central mammalian neurones by N‐methyl‐aspartate1983 · 1,418 citations