PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 2, 2023Biomedical Optics Express6 citationsOpen Access

Synthesizing the degree of polarization uniformity from non-polarization-sensitive optical coherence tomography signals using a neural network

SMShuichi MakitaMMMasahiro MiuraSAShinnosuke Azuma

Key Points

Key points are not available for this paper at this time.

Abstract

Degree of polarization uniformity (DOPU) imaging obtained by polarization-sensitive optical coherence tomography (PS-OCT) has the potential to provide biomarkers for retinal diseases. It highlights abnormalities in the retinal pigment epithelium that are not always clear in the OCT intensity images. However, a PS-OCT system is more complicated than conventional OCT. We present a neural-network-based approach to estimate the DOPU from standard OCT images. DOPU images were used to train a neural network to synthesize the DOPU from single-polarization-component OCT intensity images. DOPU images were then synthesized by the neural network, and the clinical findings from ground truth DOPU and synthesized DOPU were compared. There is a good agreement in the findings for RPE abnormalities: recall was 0.869 and precision was 0.920 for 20 cases with retinal diseases. In five cases of healthy volunteers, no abnormalities were found in either the synthesized or ground truth DOPU images. The proposed neural-network-based DOPU synthesis method demonstrates the potential of extending the features of retinal non-PS OCT.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Makita et al. (2023) studied this question.

synapsesocial.com/papers/6a65192a140fa3c74b9c4dbbhttps://doi.org/10.1364/boe.482199
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Imaging superficial tissues with polarized light2000 · 357 citations
  2. 2Detection of multiple scattering in optical coherence tomography by speckle correlation of angle-dependent B-scans2010 · 22 citations
  3. 3Object count/area graphs for the evaluation of object detection and segmentation algorithms2006 · 346 citations
  4. 4Clinical prototype of pigment and flow imaging optical coherence tomography for posterior eye investigation2018 · 26 citations
  5. 5Polarization properties of single layers in the posterior eyes of mice and rats investigated using high resolution polarization sensitive optical coherence tomography2016 · 38 citations