August 26, 2019Journal of Prosthodontic Research112 citationsOpen Access

Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering

View Full Paper
ATAkinori TasakaTSTakahiro ShimizuYKYoshimitsu Kato

Key Points

Key points are not available for this paper at this time.

Abstract

PURPOSE: The present study aimed to compare the accuracy of removable partial denture (RPD) frameworks fabricated by 3D-printed pattern casting and those fabricated by selective laser sintering (SLS). METHODS: A partially edentulous mandibular model was used for the simulation model. Scanning of the model was performed using a dental scanner. The framework was designed by using CAD software. The 3D-printed resin pattern was formed using a 3D printer and casting was performed (AM-Cast framework), and a direct metal laser sintering machine was used for the framework of SLS (SLS framework). 3D scanning of fabricated two types of framework were performed, and these data were overlapped with design data. Fabrication accuracy was verified using the Mann-Whitney U test to compare the discrepancy between the AM-Cast and SLS frameworks. RESULTS: The range of differences for the AM-Cast and SLS framework were -0.185±0.138 to 0.352±0.143mm and -0.166±0.009 to 0.123±0.009mm, respectively. Statistically significant differences were observed at the rests, proximal plates, connectors, and clasp arms. Regarding the rests, both lateral and medial displacement in the two types framework was observed in relation to the design data. Large lateral discrepancies of the connectors were observed at the joining area on the tooth-supported side of the lingual bar for the AM-Cast framework. Localized discrepancies were observed at the center of the lingual bar for the SLS framework. CONCLUSION: The accuracies of RPD frameworks fabricated by AM-Cast and SLS differ depending on the specific structural component of the RPD.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Tasaka et al. (2019) studied this question.

synapsesocial.com/papers/6a6ad21e26cff2e2f6f430a9https://doi.org/10.1016/j.jpor.2019.07.009
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1An In Vitro Investigation of Accuracy and Fit of Conventional and CAD/CAM Removable Partial Denture Frameworks2018 · 128 citations
  2. 2Assessment of the fit of removable partial denture fabricated by computer-aided designing/computer aided manufacturing technology2018 · 25 citations
  3. 3Accuracy of CAD-CAM-fabricated removable partial dentures2017 · 184 citations
  4. 4A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying2004 · 129 citations
  5. 5Accuracy of Clasps Fabricated with Three Different CAD/CAM Technologies: Casting, Milling, and Selective Laser Sintering2019 · 36 citations