December 12, 2013Catheterization and Cardiovascular Interventions37 citations

Transcatheter sapien valve implantation in a native tricuspid valve after failed surgical repair

View Full Paper
JKJoëlle KeferTSThierry SluysmansJVJean‐Louis Vanoverschelde

Key Result

Transcatheter Sapien valve implantation in a native tricuspid valve after failed surgical repairs was feasible and successfully reduced the peak gradient from 22 to 3 mm Hg.

Study Design

Type

Case Report (n=1)

Structured PICO

Is transcatheter Sapien valve implantation feasible in a native tricuspid valve after failed surgical repair?

P
Population
A 47-year-old female with mixed tricuspid disease and right heart failure after multiple failed surgical repairs underwent transcatheter Sapien valve implantation and was followed for 5 months.
I
Intervention
Transcatheter Sapien valve implantation via femoral vein, with prestenting using covered stents, under general anesthesia, ECMO, fluoroscopy, and TEE guidance.
O
Outcome
Procedural success (resolution of tricuspid leak and stenosis)surrogate

Transcatheter Sapien valve implantation in a native tricuspid valve after failed surgical repairs is feasible using prestenting and multimodality imaging guidance.

Abstract

OBJECTIVES: We describe the first report of a transcatheter Sapien implantation in a native tricuspid valve after multiple failed surgical repairs with a lack of prosthetic material and radiographic landmarks. METHODS AND RESULTS: A 47-year old female underwent multiple valve repairs and replacements including three tricuspid valve repairs without surgical ring or bioprosthesis implantation. She developed signs of right heart failure associated with a mixed tricuspid disease combining a severe stenosis and regurgitation. After surgical turn down, a revalvulation using a transcatheter approach was attempted. The challenges in this case were the absence of a stiff region to anchor the percutaneous valve, the lack of radiographic landmarks and the difficulties of precise annulus measurements. The applied strategy was -under general anesthesia and extracorporeal membrane oxygenation-: balloon sizing, prestenting of the tricuspid annulus using covered stents followed by Sapien valve implantation through the femoral vein under fluoroscopy and transoesophageal echocardiography (TEE). The procedure was successfull, solving the tricuspid leak and stenosis (peak gradient from 22 to 3 mm Hg) using two Sapien for a perfect positioning. It was complicated by pulmonary bleeding due to a distal wire exit, treated successfully by coil embolization. The clinical and echocardiographic outcome was good up to 5 months. CONCLUSIONS: Transcatheter Sapien valve implantation in a native tricuspid valve after failed multiple surgical repairs is feasible by the femoral vein. Technical challenges due to the lack of rigid landing zone and fluoroscopic markers were solved by prestenting and valve implantation under bi-plane fluoroscopic and TEE guidance.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kefer et al. (2013) conducted a case report in Mixed tricuspid disease (n=1). Transcatheter Sapien valve implantation was evaluated on Procedural success (solving tricuspid leak and stenosis). Transcatheter Sapien valve implantation in a native tricuspid valve after failed surgical repairs was feasible and successfully reduced the peak gradient from 22 to 3 mm Hg.

synapsesocial.com/papers/6a6ccd1be71d69abee079136https://doi.org/10.1002/ccd.25330
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Transcatheter Tricuspid Valve-in-Valve Replacement by Transatrial Approach2020 · 1 citations
  2. 2Failing bioprosthesis in systemic tricuspid position after a Senning procedure—Successful percutaneous tricuspid valve implantation2016 · 3 citations
  3. 3Edwards valve-in-valve implantation in tricuspid position2017 · 8 citations
  4. 4Transcatheter native pulmonary valve and tricuspid valve replacement with the sapien <scp>XT</scp>: Initial experience and development of a new delivery platform2016 · 36 citations
  5. 5Failed bioprosthetic tricuspid valve replacement treated with transcatheter valve for valve repair2024