BACKGROUND: Measuring endogenous insulin secretion using C-peptide can assist diabetes management, but standard stimulation tests are impractical for clinical use. Random non-fasting C-peptide assessment would allow testing when a patient is seen in clinic. METHODS: We compared C-peptide at 90 min in the mixed meal tolerance test (sCP) with random non-fasting blood C-peptide (rCP) and random non-fasting urine C-peptide creatinine ratio (rUCPCR) in 41 participants with insulin-treated diabetes median age 72 (interquartile range 68-78); diabetes duration 21 (14-31) years. We assessed sensitivity and specificity for previously reported optimal mixed meal test thresholds for severe insulin deficiency (sCP < 200 pmol//l) and Type 1 diabetes/inability to withdraw insulin (< 600 pmol//l), and assessed the impact of concurrent glucose. RESULTS: rCP and sCP levels were similar (median 546 and 487 pmol//l, P = 0.92). rCP was highly correlated with sCP, r = 0.91, P < 0.0001, improving to r = 0.96 when excluding samples with concurrent glucose < 8 mmol//l. An rCP cut-off of 200 pmol//l gave 100% sensitivity and 93% specificity for detecting severe insulin deficiency, with area under the receiver operating characteristic curve of 0.99. rCP < 600 pmol//l gave 87% sensitivity and 83% specificity to detect sCP < 600 pmol//l. Specificity improved to 100% when excluding samples with concurrent glucose < 8 mmol//l. rUCPCR (0.52 nmol/mmol) was also well-correlated with sCP, r = 0.82, P < 0.0001. A rUCPCR cut-off of < 0.2 nmol/ mmol gave sensitivity and specificity of 83% and 93% to detect severe insulin deficiency, with area under the receiver operating characteristic curve of 0.98. CONCLUSIONS: Random non-fasting C-peptide measures are strongly correlated with mixed meal C-peptide, and have high sensitivity and specificity for identifying clinically relevant thresholds. These tests allow assessment of C-peptide at the point patients are seen for clinical care.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hope et al. (2016) studied this question.

synapsesocial.com/papers/6a6fea33e36a167817e1a38ehttps://doi.org/10.1111/dme.13142
Ask AI
Helpful
Bookmark
Share
View Full Paper