PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 31, 2004Physics in Medicine and Biology10 citations

Effect of area x-ray beam equalization on image quality and dose in digital mammography

View Full Paper
JWJerry WongTXTong XuAHAdeel Husain

Key Points

Key points are not available for this paper at this time.

Abstract

In mammography, thick or dense breast regions persistently suffer from reduced contrast-to-noise ratio (CNR) because of degraded contrast from large scatter intensities and relatively high noise. Area x-ray beam equalization can improve image quality by increasing the x-ray exposure to under-penetrated regions without increasing the exposure to other breast regions. Optimal equalization parameters with respect to image quality and patient dose were determined through computer simulations and validated with experimental observations on a step phantom and an anthropomorphic breast phantom. Three parameters important in equalization digital mammography were considered: attenuator material (Z = 13-92), beam energy (22-34 kVp) and equalization level. A Mo/Mo digital mammography system was used for image acquisition. A prototype 16 x 16 piston driven equalization system was used for preparing patient-specific equalization masks. Simulation studies showed that a molybdenum attenuator and an equalization level of 20 were optimal for improving contrast, CNR and figure of merit (FOM = CNR2/dose). Experimental measurements using these parameters showed significant improvements in contrast, CNR and FOM. Moreover, equalized images of a breast phantom showed improved image quality. These results indicate that area beam equalization can improve image quality in digital mammography.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Wong et al. (2004) studied this question.

synapsesocial.com/papers/6a700ad4e36a167817e1c3d9https://doi.org/10.1088/0031-9155/49/16/003
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1General approach to optimizing digital mammography with respect to radiation risk2003 · 1 citations
  2. 2Image information content and patient exposure1978 · 155 citations
  3. 3Niobium/molybdenum K-edge filtration in mammography: contrast and dose evaluation1996 · 11 citations
  4. 4An approach to specifying a minimum dose system for mammography using multiparameter optimization techniques1985 · 26 citations
  5. 5Full-field digital mammography designed as a complete system1999 · 77 citations