PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
November 5, 2005European Journal of Cardio-Thoracic Surgery91 citations

Aortic root dilatation may alter the dimensions of the valve leaflets☆

View Full Paper
MTMano J. ThubrikarMLMichel R. LabrosseKZKenton J. Zehr

Structured PICO

How do the dimensions of the aortic root and leaflets change in patients with dilated aortic roots and aortic insufficiency compared to normal valves?

P
Population
14 patients with dilated aortic root and aortic insufficiency (AI), and 19 normal human aortic valves from silicone molds (total n=33).
I
Intervention
Transesophageal echocardiography and anatomical measurements of the aortic root and leaflets.
C
Comparator
19 normal human aortic valves from silicone molds.
O
Outcome
Dimensions of the aortic root and leaflets (annulus diameter, sinotubular junction [STJ] diameter, sinus height, leaflet free-edge length, and leaflet height) and correlations with AI grades.surrogate

Leaflet dimensions enlarge in parallel with aortic root dilatation, indicating that successful valve-sparing surgery may require correcting both root dilatation and leaflet free-edge length.

Abstract

OBJECTIVE: Valve-sparing surgery can be used in patients with dilated aortic roots and aortic insufficiency (AI) but has not become a common practice, in part because the spared valve may be incompetent. Our goal was to study how the dimensions of the aortic root and leaflets have changed in such patients. METHODS: Fourteen patients with dilated aortic root and AI were examined by transesophageal echocardiography. The annulus diameter, sinotubular junction (STJ) diameter, sinus height, leaflet free-edge length, and leaflet height were measured. Correlations among these dimensions and with the AI grades were explored. Measurements were also made in 19 normal human aortic valves from silicone molds. RESULTS: There was no evident change in the average diameter of the annulus between the normal valves and those in the dilated aortic roots. The STJ diameter was obviously increased in the dilated aortic roots; the aortic sinuses also appeared to be taller and the leaflets larger than normal. The leaflet free-edge length, the leaflet height, and the sinus height were found to increase with the dilated STJ diameter. The degree of AI was not found to correlate well with any of the dimensions measured. CONCLUSIONS: The dimensions of the leaflets may change parallel to aortic root dilatation with AI. Therefore, during valve sparing, it may be necessary to correct both the dilatation of the root and the leaflet free-edge length to achieve a competent valve.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Thubrikar et al. (2005) studied this question.

synapsesocial.com/papers/6a701e9bac440176ef28c3a2https://doi.org/10.1016/j.ejcts.2005.09.012
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Ascending Aortic Replacement With Aortic Valve Reimplantation1999 · 46 citations
  2. 2Ascending Aortic Replacement With Aortic Valve Reimplantation1999 · 16 citations
  3. 3Receptor-mediated contraction of aortic valve leaflets.2000 · 68 citations
  4. 4Aortic Valve Resuspension in Ascending Aortic Aneurysm Repair With Aortic Insufficiency1995 · 2 citations
  5. 5Remodeling of the aortic valve anulus1993 · 645 citations