PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 1, 2001Journal of the Optical Society of America A359 citations

Dynamics of the eye’s wave aberration

View Full Paper
HHHeidi HoferPAPablo ArtalBSBen Singer

Key Points

Key points are not available for this paper at this time.

Abstract

It is well known that the eye's optics exhibit temporal instability in the form of microfluctuations in focus; however, almost nothing is known of the temporal properties of the eye's other aberrations. We constructed a real-time Hartmann-Shack (HS) wave-front sensor to measure these dynamics at frequencies as high as 60 Hz. To reduce spatial inhomogeneities in the short-exposure HS images, we used a low-coherence source and a scanning system. HS images were collected on three normal subjects with natural and paralyzed accommodation. Average temporal power spectra were computed for the wave-front rms, the Seidel aberrations, and each of 32 Zernike coefficients. The results indicate the presence of fluctuations in all of the eye's aberration, not just defocus. Fluctuations in higher-order aberrations share similar spectra and bandwidths both within and between subjects, dropping at a rate of approximately 4 dB per octave in temporal frequency. The spectrum shape for higher-order aberrations is generally different from that for microfluctuations of accommodation. The origin of these measured fluctuations is not known, and both corneal/lenticular and retinal causes are considered. Under the assumption that they are purely corneal or lenticular, calculations suggest that a perfect adaptive optics system with a closed-loop bandwidth of 1-2 Hz could correct these aberrations well enough to achieve diffraction-limited imaging over a dilated pupil.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Hofer et al. (2001) studied this question.

synapsesocial.com/papers/6a708c7e8031ec7bb1dc6b4dhttps://doi.org/10.1364/josaa.18.000497
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Estimates of the ocular wave aberration from pairs of double-pass retinal images1998 · 60 citations
  2. 2A subjective method for the measurement of monochromatic* aberrations of the eye1977 · 388 citations
  3. 3Fluctuations in accommodation: a review1988 · 267 citations
  4. 4Topical measurement of fundus pulsations1995 · 125 citations
  5. 5Pupil meter and tracking system based in a fast image processing algorithm1999 · 9 citations