May 14, 2021International journal of cardiac imaging21 citationsOpen Access

Implantation depth and its influence on complications after TAVI with self-expanding valves

PBPhilipp BreitbartJMJan MinnersMHManuel Hein

Structured PICO

Does a lower implantation depth (≥ 4 mm) increase the risk of new conduction disturbances or paravalvular leakage in patients undergoing TAVI with self-expanding valves?

P
Population
104 patients undergoing transcatheter aortic valve implantation (TAVI) with a self-expanding valve (Evolut R) who had evaluable pre- and post-TAVI computed tomography angiography (CTA). Mean age 82.2 years, 66.3% female. Excluded patients with valve-in-valve procedures.
I
Intervention
Lower transcatheter heart valve (THV) positioning, defined as an implantation depth of ≥ 4 mm below the native annulus.
C
Comparator
Higher transcatheter heart valve (THV) positioning, defined as an implantation depth of < 4 mm below the native annulus.
O
Outcome
Occurrence of new conduction disturbances (CD) and grade of paravalvular leakage (PVL) assessed pre-discharge.safety

In TAVI using self-expanding valves, an implantation depth of ≥4 mm below the annulus significantly increases the risk of new conduction disturbances without affecting the severity of paravalvular leakage.

Limitations

  • Limited sample size
  • Low prevalence of right bundle branch block
  • Limited to patients with one specific self-expanding valve type (Evolut R)

Abstract

Prior studies in patients with transcatheter aortic valve implantation (TAVI) demonstrated an influence of transcatheter heart valve (THV) position on the occurrence of new conductions disturbances (CD) and paravalvular leakage (PVL) post TAVI in balloon-expandable valves (BEV). Purpose of this study was to investigate the THV implantation depth and its influence on the occurrence of CD and PVL in self-expanding valves (SEV). We performed fusion imaging of pre- and post-procedural computed tomography angiography in 104 TAVI-patients (all with Evolut R) to receive a 3-D reconstruction of the THV within the native annulus region. The THV length below the native annulus was measured for assessment of implantation depth. Electrocardiograms pre-discharge were assessed for conduction disturbances (CD), PVL was determined in transthoracic echocardiography. The mean implantation depth of the THV in the whole cohort was 4.3 ± 3.0 mm. Using the best cut-off of ≥ 4 mm in receiver operating characteristic curve analysis (sensitivity 83.3%, specificity 60.0%) patients with lower THV position developed more new CD after TAVI (68.2 vs. 23.7%, P < 0.001). A deep THV position was identified as the only predictor for new CD after TAVI (odds ratio CI 1.3121.119-1.539, P = 0.001). The implantation depth showed no influence on the grade of PVL (r = 0.052, P = 0.598). In patients with TAVI using the Evolut R SEV, a lower THV positioning (≥ 4 mm length below annulus) was a predictor for new conduction disturbances. In contrast, implantation depth was not associated with the extent of PVL. Prostheses positions of self-expanding valves and their influence on the occurrence of new conduction disturbances and the grade of paravalvular leakage after TAVI.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Breitbart et al. (2021) studied this question.

synapsesocial.com/papers/6a709c3a2163a0a01bc4d1a7https://doi.org/10.1007/s10554-021-02275-3
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Chronic pacing and adverse outcomes after transcatheter aortic valve implantation2015 · 131 citations
  2. 2One‐year safety and efficacy profile of transcatheter aortic valve‐in‐valve implantation with the portico system2020 · 8 citations
  3. 3Predictors for low TAVI-prosthesis position assessed by fusion imaging of pre- and post-procedural CT angiography2020 · 9 citations
  4. 4Incidence, Predictors, and Outcome of Paravalvular Leak after Transcatheter Aortic Valve Implantation2020 · 45 citations
  5. 5Optimized Implantation Height of the Edwards SAPIEN 3 Valve to Minimize Pacemaker Implantation After TAVI2016 · 43 citations