Left ventricular internal resistance and unloaded ejection flow assessed from pressure-flow relations: a flow-clamp study on isolated rabbit hearts.

View Full Paper
SVS. R. VaartjesHBH.B.K. Boom

Key Points

Key points are not available for this paper at this time.

Abstract

Left ventricular pressure-flow relations were studied, using excised working rabbit hearts and imposing constant flow ejections (flow-clamps) to separate the effects of flow on pressure from those of time, flow duration, starting volume, ejected volume, and volume at specified time. Pressure-flow data at given volume and time were independent of flow duration, starting volume, and ejected volume for flow-clamp durations exceeding 30 msec. Flow history independent of pressure-flow relations was linear for flow values larger than +/- 5 ml/sec. The time-varying elastance model, E(t), of the ventricle was extended with a resistive component. Transient effects of flow can be explained by including a second elastance. The resulting verified 3-component model is consistent with recent reported experimental findings. The properties of internal resistance correspond to a constant unloaded ejection flow Qmax, which was tested by extrapolating the linear pressure-flow relations to zero pressure. Qmax reached a plateau value of approximately 25 ml/sec within 50 msec after the start of contraction. In relaxation, Qmax is only slightly smaller. Qmax did not depend on volume; therefore, the following equation was adequate for the relation between pressure, p(t); volume, V(t); and flow Q(t), during the flow-clamped ejections from 30 minutes after the start of the flow: (t) = E(t).(V(t)-Vd).(1-Q(t)/Qmax)

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Vaartjes et al. (1987) studied this question.

synapsesocial.com/papers/6a70abdefe4101aa97e04428https://doi.org/10.1161/01.res.60.5.727
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Left-ventricular dynamic model based on constant ejection flow periods1991 · 7 citations
  2. 2Description of LV pressure-volume relations by time-varying elastance and source resistance1987 · 41 citations
  3. 3Pressure-velocity relation in the isolated rabbit left ventricle.1983 · 6 citations
  4. 4Deactivation in the rabbit left ventricle induced by constant ejection flow1989 · 12 citations
  5. 5Evidence and quantitation of left ventricular systolic resistance1985 · 105 citations