PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 1, 2014Journal of Medical Ultrasound10 citationsOpen Access

Ultrasonography for Proper Endotracheal Tube Placement Confirmation in Out-of-hospital Cardiac Arrest Patients: Two-center Experience

JSJen‐Tang SunHCHao‐Chang ChouSSShyh‐Shyong Sim

Key Points

Key points are not available for this paper at this time.

Abstract

A secure airway and effective ventilation are key components of resuscitation. Real-time airway sonographic approaches could enhance physician confidence and decision-making in relation to tracheal tube placement. This study aims to evaluate the accuracy of tracheal ultrasonography for assessing endotracheal tube position in patients at two medical centers who have undergone cardiac arrest. We performed a prospective two-center observational study for adult patients with cardiac arrest from July 2012 to June 2013. Real-time tracheal ultrasonography was performed during the intubation. The endotracheal tube position was defined as endotracheal if single air-mucosa interface with comet-tail artefact was observed. Esophageal intubation was defined if a second air-mucosa interface appeared. The gold standard of correct endotracheal intubation was the combination of clinical auscultation and quantitative waveform capnography. The main outcome was the accuracy of tracheal ultrasonography in assessing endotracheal tube position during cardiopulmonary resuscitation. Among the 96 patients enrolled, 7 (7.3%) had esophageal intubations. The sensitivity, specificity, positive predictive value, and negative predictive value of tracheal ultrasonography were 98.9% 95% confidence interval (CI): 94.0–99.8%, 100% (95% CI: 61–100.0%), 100% (95% CI: 95.9–100.0%), and 85.7% (95% CI: 48.7–97.4%), respectively. Positive and negative likelihood ratios were 7.0 (95% CI: 1.1–43.0) and 0.0, respectively. Additionally, subgroup analysis was performed based on the hospital. However, no significant difference existed in the accuracy of tracheal ultrasonography and patient characteristics. Real-time tracheal ultrasonography is an accurate method for identifying endotracheal tube position during cardiopulmonary resuscitation without the need for interruption of chest compression.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Sun et al. (2014) studied this question.

synapsesocial.com/papers/6a70e437febe604dd709a855https://doi.org/10.1016/j.jmu.2014.05.004
Ask AI
Helpful
Bookmark
Share
View Full Paper