PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
July 7, 2020Biosensors43 citationsOpen Access

Factors Influencing the Long-Term Stability of Electronic Tongue and Application of Improved Drift Correction Methods

ZKZoltán KovácsDSDániel SzöllősiJZJohn‐Lewis Zinia Zaukuu

Key Points

Key points are not available for this paper at this time.

Abstract

Temperature, memory effect, and cross-contamination are suspected to contribute to drift in electronic tongue (e-tongue) sensors, therefore drift corrections are required. This paper aimed to assess the disturbing effects on the sensor signals during measurement with an Alpha Astree e-tongue and to develop drift correction techniques. Apple juice samples were measured at different temperatures. pH change of apple juice samples was measured to assess cross-contamination. Different sequential orders of model solutions and apple juice samples were applied to evaluate the memory effect. Model solutions corresponding to basic tastes and commercial apple juice samples were measured for six consecutive weeks to model drift of the sensor signals. Result showed that temperature, cross-contamination, and memory effect influenced the sensor signals. Three drift correction methods: additive drift correction based on all samples, additive drift correction based on reference samples, and multi sensor linear correction, were developed and compared to the component correction in literature through linear discriminant analysis (LDA). LDA analysis showed all the four methods were effective in reducing sensor drift in long-term measurements but the additive correction relative to the whole sample set gave the best results. The results could be explored for long-term measurements with the e-tongue.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Kovács et al. (2020) studied this question.

synapsesocial.com/papers/6a717be83ce530166bc31b8ehttps://doi.org/10.3390/bios10070074
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Effective resolution and drift of Paroscientific pressure sensors derived from long‐term seafloor measurements2009 · 153 citations
  2. 2An improved calibration method for the drift of the conductivity sensor on autonomous CTD profiling floats by θ–S climatology2008 · 145 citations
  3. 3An Intelligent ISFET Sensory System With Temperature and Drift Compensation for Long-Term Monitoring2008 · 60 citations
  4. 4Artificial Taste Sensor: Efficient Combination of Sensors Made from Langmuir−Blodgett Films of Conducting Polymers and a Ruthenium Complex and Self-Assembled Films of an Azobenzene-Containing Polymer2001 · 189 citations
  5. 5Encapsulation of ISFET sensor chips2004 · 73 citations