PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
May 12, 2008Acta Radiologica16 citations

Evaluation of accordance of magnetic resonance volumetric and flow measurements in determining ventricular stroke volume in cardiac patients

View Full Paper
MJMichael JeltschSRS. RanftOKOliver Klass

Key Points

  • The aim is to assess the accuracy of stroke volume quantification using MR volumetric imaging compared to flow quantification in cardiac disease patients.
  • 78 patients with varied cardiac diseases underwent flow measurements across the aortic root and cine imaging of the left ventricle.

Structured PICO

Does MR volumetric imaging correlate with flow quantification for determining ventricular stroke volume in patients with cardiac diseases?

P
Population
78 patients with various cardiac diseases (excluding intra- or extracardiac shunts, regurgitant valvular defects, or heart rhythm disturbance)
I
Intervention
Stroke volume quantification using MR volumetric imaging (cine imaging of the ventricles)
C
Comparator
Flow quantification across the aortic root or pulmonary trunk
O
Outcome
Correlation and agreement (Bland-Altman analysis) between volumetric and flow measurements of stroke volumesurrogate

Flow quantification across the great vessels correlates highly with volumetric measurements and can be used to accurately and rapidly gauge ventricular stroke volume in clinical routine.

Abstract

BACKGROUND: Cardiovascular magnetic resonance imaging (CMR) has become an established noninvasive method for evaluating ventricular function utilizing three-dimensional volumetry. Postprocessing of volumetric measurements is still tedious and time consuming. Stroke volumes obtained by flow quantification across the aortic root or pulmonary trunk could be utilized to increase both speed of workflow and accuracy. PURPOSE: To assess accuracy of stroke volume quantification using MR volumetric imaging compared to flow quantification in patients with various cardiac diseases. Strategies for the augmentation of accuracy in clinical routine were deduced. MATERIAL AND METHODS: 78 patients with various cardiac diseases-excluding intra- or extracardiac shunts, regurgitant valvular defects, or heart rhythm disturbance-underwent cardiac function analysis with flow measurements across the aortic root and cine imaging of the left ventricle. Forty-six patients additionally underwent flow measurements in the pulmonary trunk and cine imaging of the right ventricle. RESULTS: Left ventricular stroke volume (LVSV) and stroke volume of the aortic root (SVAo) correlated with r=0.97, and Bland-Altman analysis showed a mean difference of 0.11 ml and a standard error of estimation (SEE) of 4.31 ml. Ninety-two percent of the data were within the 95% limits of agreement. Right ventricular stroke volume (RVSV) and stroke volume of the pulmonary trunk (SVP) correlated with a factor of r=0.86, and mean difference in the Bland-Altman analysis was fixed at -2.62 ml (SEE 8.47 ml). For RVSV and SVP, we calculated r=0.82, and Bland-Altman analysis revealed a mean difference of 1.27 ml (SEE 9.89 ml). LVSV and RVSV correlated closely, with r=0.91 and a mean difference of 2.79 ml (SEE 7.17 ml). SVAo and SVP correlated with r=0.95 and a mean difference of 0.50 ml (SEE 5.56 ml). CONCLUSION: Flow quantification can be used as a guidance tool, providing accurate and reproducible stroke volumes of both ventricles. Combining both offers a highly accurate tool to gauge ventricular function in a routine clinical setting, increasing workflow speed.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Jeltsch et al. (2008) studied this question.

synapsesocial.com/papers/6a718b1026a7f98052ddd95ahttps://doi.org/10.1080/02841850801998847
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Right and left ventricular stroke volume measurements with velocity-encoded cine MR imaging: in vitro and in vivo validation.1991 · 262 citations
  2. 2In Vivo Validation of MR Velocity Imaging1987 · 339 citations
  3. 3Heart motion adapted cine phase‐contrast flow measurements through the aortic valve1999 · 108 citations
  4. 4Effect of breath holding on blood flow measurement using fast velocity encoded cine MRI2001 · 82 citations
  5. 5Rapid assessment of left ventricular volume by short axis cine MRI1996 · 20 citations